CHAPTER 7
Instructions, use and maintenance manual
D r a g o P Z e r o
Page 57
7.3. ROUTINE MAINTENANCE
When the burner is delivered to the user, it is already adjusted for correct operation; nonetheless, to ensure good
operation over time, it is necessary to carry out checks as well as periodic and preventive maintenance.
Routine maintenance includes inspections, checks and interventions that, in order to prevent faults, monitor:
• the mechanical conditions of the machine,
• the lubrication of the machine,
•
machine cleanliness.
The following tables list a series of controls and activities that need to be carried out according to the recommended
frequency. The frequency of the routine maintenance activities listed here refer to normal operating conditions,
i.e. that fulfil the required operating conditions.
7.3.1. ROUTINE MAINTENANCE TABLE
OPERATION
FREQUENCY
Daily
1 month
2 months
6 months
Visually check the integrity of all the machine's
protective devices.
♦
Visually check the wear and cleanliness conditions.
♦
Check the proper operation of the electrical trigger.
♦
Check the proper tightening of the gas fittings.
♦
Check the wear of the insulation (connection cables,
connectors).
♦
Check the fastening devices of the protections.
♦
Check adjustment operation.
♦