5.9.1. NATURAL GAS CONNECTION
Follow the procedure below to connect to the natural gas network:
STEP
ACTION
1
Connect the gas supply to the 1/2” male fitting “
A
” on the burner with a flexible hose (not supplied).
2
Make sure that the pressure at the pressure point “
B
” is included between 17 and 23 mbar.
A
A
B
CAUTION!
PERIODICALLY CHECK THAT THE OPERATING PRESSURE IS CORRECT.
In case of insufficient pressure, the burner may experience malfunctions or switch off.