background image

3

4

AVANTI Service Lift for Wind Turbines 

This instruction is a supplementary part of the Daily Lift 
Checking to be used by authorized users and Certified 
technicians. The information describes a recommended 
and supplementary way of how to check the over speed 
triggering and arresting function in the Avanti Safety Fall 
Arrest Device model ASL. Second, the test also 
documents that the Safety Brake maintains its grip on 
the Safety Wire after engagement. This extra testing we 
name the “Stomp-test”.

This stomp-test-method is supplementary to the given 
daily obligation in your manual explaining “to descend 
the lift, manually engage the FAD (Fall Arrest Device), 
verification by short no-powerdescent, unloading the 
FAD again by ascending and observing centrifugal weigh 
unit through the window during lift use”. With the

“Stomp-test” we test the ability of the FAD to trigger in 
case of over speed and arrest the load.

Tools: 

None

Measurement Equipment: 

None

Validity 

It is applicable for testing the installed Safety Fall Arrest 
Device (ASL) on-site. The test must only be performed by 
trained users/Certified technicians and always with 
respect of all the relevant safety regulations. 

Cautions 

Be aware that the instruction only explains the steps of 
how to execute the “Stomp test” in the lift installation; it 
doesn’t guide any safety precautions and the necessary 
use of safety equipment.

Therefore, Avanti strongly recommends you to read and 
understand what the physical work steps in the “Stomp-
test” are, and then execute your own Risk and Hazard 
Assessment according to the valid safety working 
procedures in your own organisation before starting the 
test. 

1. Test Preparation

The cabin (with 1 person inside) is ascended with a 
service lift user inside, and the cabin bottom is 
positioned (“parked”) in a height of app. 3 m/10 ft. above 
the bottom landing floor platform. 

With the cabin in “parked” position app. 3 m/10 ft. above 
the bottom landing floor, the user starts descending by 
electrical power using the push down button. When the 

cabin starts descending the user executes a hard stomp 
with one foot in the cabin floor – The hard stomp is 
executed by lifting one foot, so the lower leg is positioned 
with a knee angle of 90 degrees – Then immediately after 
the foot is stomped in the cabin floor - 

-The user must make sure to have a solid footing during 
the foot stomp!

The foot stomp should engage the ASL and arrest the 
electrical descent of the cabin, the red light (if existing in 
the control box) should turn “on” and the cabin load 
should be hanging on the FAD/Safety Wire.

If the ASL doesn’t arrest at the first trial, then  
re-establish the cabin in the position described in the 
preparation part mentioned above and execute the  
“Step” once again stomping a little harder.  

3. Test Result

If the ASL activates properly after the stomp, the ASL will 
now hold the cabin on the Safety Wire.

In order to ensure important maintaining grip by the 
Safety Brake, the user then activates the manual descent 
function and result shall be a Safety Fall Arrest Device 
ASL holding the cabin fixed on the Safety Wire  
(manual descending is not possible).

- If the activated ASL fixes the cabin on the Safety Wire
while manual descent is activated, the Safety Fall Arrest
Device (ASL) is in good and operational condition.

In order to release the activated ASL push the ascent 
button up a little before releasing the ASL by the 
unlocking handle.

-

If the ASL can´t activate 

after first or second

“Stomp-test”, or can´t fix the cabin in activated position
- User 

must

 immediately bring the cabin down and

park it at the bottom landing platform floor.

- Lock Out the installation from use and contact Avanti
for further approach!

- Document the execution of the above described
procedure in the Daily Inspection Log Appendix.

Any doubts regarding above instruction, please do not 
hesitate to contact Avanti’s local representative for help. 
- www.avanti-online.com

Appendix 

B

: Stomp-test Instruction 

Supplementary way to inspect the ASL during Daily Inspection before Operation

Purpose 2. Test Step

Содержание OCTOPUS L95

Страница 1: ...AVANTI SERVICE LIFT User s Manual Model Service Lift OCTOPUS L95 Original instructions ...

Страница 2: ...CE certificate for Octopus L95 ...

Страница 3: ...Systems Technology S L Calle Ángeles Los Num 88 Pol Industrial Centrovía 50198 Muela La Zaragoza Spain P 34 976 149524 F 34 976 149508 E info avanti online com I www avanti online com Manufactured Under Process Patent NO 8 499 896 Registered in Europe Sales Service avanti online com contact ...

Страница 4: ...evice 14 3 6 14 Top obstruction device 15 3 6 15 Top normal limit switch 15 3 6 16 Manual descent system 15 3 6 17 Overload limiter 15 3 6 18 Internal light 16 3 6 19 Warning lights 16 3 6 20 Anchor points 16 3 6 21 Rescue pendant control 16 3 6 22 Information signs and documents 16 3 6 23 Travelling cable pulley 17 3 6 24 Fasten kit 17 4 Instructions for use 18 4 1 Daily inspection 18 4 2 Prohibi...

Страница 5: ... ii has not been installed operated repaired or maintained in accordance with this Manual or other instructions from Avanti iii has been subjected to abuse neglect casualty or negligence iv has been furnished by Avanti to Customer without charge or v has been sold on an AS IS basis Except as specifically set forth in this Limited Warranty ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRA...

Страница 6: ...om any changes in the manuals does not entitle Customer to any form of compensation or other legal remedies The pictures and sketches in this manual may not reflect the product aesthetics colours arrangement precisely This has no impact on the function or safety STOP Symbol Signal word Meaning Possible injury if not observed Safety instructions DANGER IMMEDIATE or possibly imminent danger Death or...

Страница 7: ...nicians Personnel must be at least 18 years of age The staff must be familiar with the relevant accident prevention instructions and must have received proper training in these Personnel are obliged to read and understand this User s Manual Personnel shall wear PPE safety helmet full body harness shock absorber lanyard and slider at all times A copy of the User s Manual must be handed out to the p...

Страница 8: ...g temperature ranges in particular there is a standard configuration and a low temperature configuration where traction system and main control box components are chosen specifically 3 3 Exclusions The service lift shall not be used outdoor or in potentially explosive atmospheres The service lift is not designed to carry a person on its top The wind turbine manufacturer is responsible of integrati...

Страница 9: ...9 User s Manual 3 5 Dimensions 1040 2680 2750 970 960 ...

Страница 10: ... light 4 Anchor points 5 Maintenance cover 6 Cabin control box 7 Bottom obstruction device 8 Guide ladder 9 Guiding rollers 10 Main control box 11 Hour counter 12 Ladder access door 13 Full sliding door 14 External controls 15 Top obstruction device 16 Safety wire rope 17 Traction wire rope 18 Travelling cable pulley ...

Страница 11: ...1 8 4 1 8 4 50 Octopus L95 M508 690V 60Hz 500 21 1 8 2 8 8 4 55 Traction system Fall arrest device 3 6 3 Fall arrest device 3 6 4 Traction and safety wire ropes Service Lift Fall arrest device Lifting capacity Safety wire rope Ø Unit weight approx Version Type Kg lbs mm Kg lbs OctopusL95 ASL 508 500 1100 8 4 7 15 4 Service Lift Version Wire rope type Wire rope diameter Surface Treatment Mark featu...

Страница 12: ...for send function Override key of bottom obstruction switch DOWN button Platform level lamp Ready lamp Emergency stop button UP button Main switch Fall arrest device triggered lamp Internal DOWN button for manual function Internal UP button for manual function Trapped key switch optional for Octopus L95 Internal emergency stop button Platform level lamp OK lamp Overload buzzer Warning buzzer Hour ...

Страница 13: ...vice lift door Main access to the cabin is done through the full sliding door installed on the front The full sliding door opening dimensions are 1950 x 500 mm It features a guard locking system that Prevents service lift to travel if the door is open This opening condition is monitored by the guard locking switch Permits door to be opened only when service lift is levelled with a platform This le...

Страница 14: ...a safety switch that interrupts control when hatch is opened Top obstruction device hatch opens outwards Once top hatches and ladder access door are open clear area is at least 500 x 500 mm and ladder becomes totally accessible 3 6 13 Bottom obstruction device Bottom obstruction device interrupts descent if It encounters an obstacle It reaches the bottom platform Ascent will still be possible for ...

Страница 15: ... system that can be used in case of emergency To activate it push the manual descent actuator fully upwards The electromagnetic motor brake is released The service lift descends with a controlled speed limited by means of a centrifugal brake installed between the motor shaft and the gear box 3 6 17 Overload limiter An overload limiter is built into the traction hoist In case of an overload it will...

Страница 16: ...he evacuation procedure will be followed 3 6 21 Rescue pendant control 1 Rescue pendant control is only mandatory if rescue route of service lift can be somehow blocked A blocked rescue route is an event where A person is unconscious inside the service lift blocking the bottom hatch the rescuer is below service lift and the service lift is stopped halfway through a platform hole blocking rescue ro...

Страница 17: ...hazardwarninglabel Bottomplatform Rescuependantcontrolemergencysign1 3 6 23 Travelling cable pulley Travelling cable is connected from power supply socket over mid tower s height platform to service lift socket and it is provided with a cable relief on each end A travelling cable pulley is suspended on the cable and is guided along the traction and safety wire ropes The travelling cable pulley str...

Страница 18: ...vice activate device by pressing it down The service lift shall not move up until device is released If any faults occur during work stop working if required secure the workplace and rectify the fault Make sure that nobody is exposed to danger below the service lift for instance from falling parts g Fall arrest device Activate the fall arrest device by pulling down the red locking handle Press and...

Страница 19: ...on the floor after the bottom obstruction device has stopped the lift Turn the override bottom obstruction device switch clockwise and hold Press the DOWN button until the service lift rests on the floor then release 4 6 Operation from outside the cabin automatic send configuration Transportation of people is forbidden if the operation is controlled from outside the cabin Operation by means of the...

Страница 20: ...Push the lever upwards the full way The service lift moves downwards The built in mechanical overspeed limiter limits the pace of descent 3 To stop simply loosen the lever 4 After manual descent the system must be checked by an expert During manual descent if the bottom obstruction device hits an obstacle the brake release lever is mechanically disengaged so the further descent is disabled The sys...

Страница 21: ...ing from the control box A6 Safety switch is triggered a EMERGENCY top limit switch was pressed b Door switch is not properly closed or is defective c Ladder access door switch is activated d A top or bottom hatch switch is triggered a Perform manual descent until the emergency top limit switch is released b Close the door and test the door switch c Close the door d Close the hatch A7 Protection s...

Страница 22: ... Overload Buzzer sounds in the connection cabinet Test and possibly reduce load until buzzer stops B3 Top obstruction switch a Top obstruction switch is defective or not connected properly b Top obstruction switch is activated a Test the top obstruction switch connec tion function Replace if necessary b Move lift down until the top obstruction switch is released B4 A phase is missing Test fuses an...

Страница 23: ... switch a Bottom obstruction switch is defective or not connected properly b Bottom obstruction switch is activated a Test the bottom obstruction switch connection function Replace if necessary b Move lift up until the bottom obstruction switch is released Button lamp not lit although operation is normal E A lamp is defective Have an electrician replace it Hoist goes down when up button is pressed...

Страница 24: ...ttom landing floor the user starts descending by electrical power using the push down button When the cabin starts descending the user executes a hard stomp with one foot in the cabin floor The hard stomp is executed by lifting one foot so the lower leg is positioned with a knee angle of 90 degrees Then immediately after the foot is stomped in the cabin floor The user must make sure to have a soli...

Страница 25: ...35 User s Manual ...

Страница 26: ...I www avanti online com E info avanti online com AT00012569 Octopus L95 User s manual EN 3rd CE Edition 07 2019 Revision 1 30 07 2019 avanti online com contact ...

Отзывы: