background image

- 7 -

User Manual

Startup

-  Temperature control set at No . 4 position gives refrigerators an approximate temperature of 35°F .

  Allow unit to function several hours, completely cooling cabinet before changing the

  control setting .
-  Excessive tampering with the control could lead to service difficulties . Should it ever become

  necessary to replace temperature control, be sure it is ordered from your Avantco dealer or

  recommended service agent .
-  Good air flow in your unit is critical . Be careful to load product so that it neither presses against

  the back wall, nor comes within four inches of the evaporator housing . Refrigerated air off the coil

  must circulate down the back wall .

Recommendation:

Before loading product, we recommend you run your Avantco unit empty for 2-3 days . This allows 

you to be sure the electrical wiring and installation are correct and no shipping damage has 

occurred . Remember, the Avantco factory warranty 

does not

 cover product loss!

set

mute

Dial Controls

Digital Controls

Temperature Setting

Dial Controls (UDD1 & UDD1S ONLY)

Temperature range from (7) Coldest to (1) Warmest

Digital Controls (All Other Models)

Refrigerators are programmed to operate between 33 and 40°F

To set the temperature you would like your unit to run at:
1 .  Hold “SET” for 1 sec . The display will flash the temperature

  that the refrigerator is currently set to .
2 . Use the arrow buttons to adjust the temperature .
3 . Press “SET” to save your settings .
If the unit consistently runs 5+ degrees higher than your set 

temperature, service may be needed .

Note: All other control functions should only be performed

by a trained service technician.

Drain Instructions

On direct draws, the drain is located at the front of the cabinet .
(UDD1 & UDD1S drain into a bottle located inside the unit)
To plumb in the drain, connect ½” PVC pipe to the barbed fitting supplied with the unit .
If you would prefer to drain the beer inside the unit (for mobility or where a drain can’t be found):
 

- Use a screwdriver to remove the drain bracket .

 

- Pull the drain hose so that it is inside the unit .

 

- Attach a bottle to the drain hose inside the unit .

 

- Plug the created hole at the bottom of the unit

Содержание UDD1

Страница 1: ...Beer Dispenser User s Manual 1 User Manual UDD1 UDD1S UDD2448 UDD2448S UDD2460 UDD2460S UDD2472 UDD2472S Please read the manual thoroughly prior to equipment set up operation and maintenance 07 2015...

Страница 2: ...llation 9 Changing CO2 Gas Cylinder 10 CO2 Pressure Adjustment 10 Cleaning the Bar System 11 Cleaning the Condenser Coil 12 Cleaning the Fan Blade and Motor 12 Cleaning the Interior of the Unit 12 Sta...

Страница 3: ...unit on strong and level surfaces keep the cooler stable to avoid vibration and noise Install the unit in an indoor well ventilated area A space of at least 3 should be allowed between the surrounding...

Страница 4: ...t a terrible accident Remove the doors Leave shelves in place to prevent children from easily climbing inside Do not allow children to climb stand or hang on the shelves in the cooler They could damag...

Страница 5: ...prong outlet it must be replaced with the properly grounded wall outlet NEVER USE AN ADAPTER PLUG Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is proper...

Страница 6: ...ure draft arm with four screws 5 Insert air hose in draft arm being careful not to disturb insulation 6 Remove top cover of draft arm and attach air hose clip to the insulating sleeve at the top of th...

Страница 7: ...trols Digital Controls Temperature Setting Dial Controls UDD1 UDD1S ONLY Temperature range from 7 Coldest to 1 Warmest Digital Controls All Other Models Refrigerators are programmed to operate between...

Страница 8: ...t in good repair Tapping Do not agitate the kegs unnecessarily If excessive agitation occurs allow kegs to settle for 1 2 hours before tapping Prior to tapping the keg ensure that all beer faucets in...

Страница 9: ...CO2 Installation These is the recommended procedure for installing a remote CO2 container in your Avantco unit 1 Remove black knockout plug with pliers See images below for plug locations 2 Use drill...

Страница 10: ...the ring F on the pressure release valve on the body of the tap 10 Tap keg at D with valve C open Note DO NOT drop cylinders DO NOT lay cylinders flat It requires 1 2 lb of CO2 to dispense 1 2 barrel...

Страница 11: ...hose from pump bottle to beer column tap outlet be sure rubber gasket is in place to prevent leakage Allow tap to drain into bucket 9 Pump solution 2 3 times from bottle through the line until it sta...

Страница 12: ...revent moisture damage Cleaning the Interior of the Unit When cleaning the cabinet interior use a solution of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach th...

Страница 13: ...n All Purpose Citrus Cleaner Degreaser Heavy duty citrus cleaner removes tough grease dirt and mineral build ups without damaging stainless steel Its natural citrus solvent leaves behind a pleasant or...

Страница 14: ...cleaners containing quaternary salts as they can attack stainless steel causing pitting and rusting 4 Water Treatment To reduce deposits soften the hard water when possible Installation of certain fil...

Страница 15: ...er Unplug the unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet Temperature is too Warm Thermostat is at wrong temperature...

Страница 16: ...mperature Research or consult your supplier for proper temps pressures for each draft product Coils in beer lines warmer than beer in keg Check that the air hose clip is still in place Check insulatio...

Страница 17: ...ons Cloudy Beer Dirty glass or faucet Clean glasses and faucet thoroughly before use Beer over chilled or frozen Check temperature setting in unit and storage area Beer temperature variance in keg Che...