Inspection
When the equipment is received, all items should be carefully checked against the bill of landing
to insure all crates and cartons have been received. All units should be inspected for concealed
damage by uncrating the units immediately. If any damage is found, it should be reported to the
carrier at once, and a claim should be filed with the carrier. This equipment has been inspected and
tested in the Avantco Refrigeration. Facility and has been crated in accordance with transportation
rules and guidelines. Manufacturer is not responsible for freight loss or damage.
Installation
GENERAL
Take care when removing the skid, so that it will not damage the cooler’s finish. Do not tip cabinet to
install casters or legs. Insure that the casters or legs are screwed all the way into the base.
LOCATION
The self contained refrigeration system located at the bottom of the cabinet requires free air access
for proper operation. The back of the cabinet may be positioned against a wall, however, there must
be a minimum four inch clearance between the sides and a wall. It is necessary to properly level
cooler to provide adequate drainage and efficient functioning of the unit.
ELECTRICAL
Check the proposed outlet to be used to insure that the voltage, phase, and current carrying
capacity of the circuit from the electrical panel correspond to the requirements of the cabinet. Plug
all standard models into a 110 volts A.C.60 cycle outlet. NEVER use an extension cord to power
any unit. All wiring between the electrical panel and the unit must be done in accordance with the
National Electric Code and all state and local codes. Refer to the Serial Tag for all pertinent electrical
information.