Troubleshooting

Compressor Not Running

 

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit breaker.

Power cord unplugged.

Plug in power cord.

Thermostat set too high.

Set thermostat to lower temperature.

Cabinet in defrost cycle.

Wait for defrost cycle to finish.

Condensing Units Run For Long Periods of Time.

Excessive amount of warm product placed in cabinet.

Allow adequate time for product to cool down.

Prolonged door opening or door ajar.

Ensure doors are closed when not in use. Avoid 
opening doors for long periods of time.

Door gasket(s) not sealing properly.

Ensure gaskets are snapped in completely. Remove 
gasket and wash with soap and water. Check condition 
of gasket and replace if necessary.

Dirty condenser coil.

Clean the condenser coil.

Evaporator coil iced over.

Unplug unit and allow coil to defrost. Make sure 
thermostat is not set too cold. Ensure that door 
gasket(s) are sealing properly.

Cabinet Temperature is too Warm.

Thermostat set too warm.

Set thermostat to lower temperature.

Airflow blocked.

Re-arrange product to allow for proper air flow. 
Make sure there is at least four inches of clearance 
from evaporator.

Excessive amount of warm product placed in cabinet.

Allow adequate time for product to cool down.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit breaker.

Dirty condenser coil.

Clean the condenser coil.

Evaporator coil iced over.

Ensure doors are closed when not in use. Avoid 
opening doors for long periods of time.

Содержание 178AU27FHC

Страница 1: ...nd Freezers with Backsplash Commercial Refrigerator And Freezer User s Manual 1 User Manual Please read the manual thoroughly prior to equipment set up operation and maintenance 08 2022 178AU27FHC 178...

Страница 2: ...IGORIG NE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION D...

Страница 3: ...all the unit in an indoor well ventilated area For best performance please maintain clearance of 4 on the back of the unit Brackets should be attached on the back of the unit Outdoor use may cause dec...

Страница 4: ...frigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freezers are set to cycle between a minimum temperature of 5 degr...

Страница 5: ...es at preset intervals However if you would like to run a manual defrost cycle at any time please follow the steps below Freezers Press the defrost button def and down arrow for approximately 5 second...

Страница 6: ...east 10 minutes before plugging it back in Failure to do so could cause damage to the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands Dur...

Страница 7: ...and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning The Interior of Unit When cleaning the cabinet interior use a solvent of...

Страница 8: ...sket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make...

Отзывы: