Loading Product

Before loading shelves, please be sure that all shelf clips are completely fastened in their correct 
locations. It is important that all shelves rest completely level before stocking your cabinet with product.
In order to maintain correct air flow inside the unit, please be sure to leave two to four (2 to 4) inches 
of space between the back wall and stored product. Blocking the evaporator fans will result in a 
warmer cabinet temperature, and ultimately compressor failure.

Running a Manual Defrost Cycle

This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you 
would like to run a manual defrost cycle at any time, please follow the steps below:

Freezers: Press the defrost button (“def” and down arrow) for approximately 5 seconds. Repeat to 

stop the defrost cycle. 

Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3 

seconds. Repeat to stop the defrost cycle.

Defrost Systems

Refrigerator coils are kept below the freezing point (32° F). During compressor down-time, the 
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil 
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into 
the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost timers 
automatically initiate at pre-set intervals and for a pre-determined duration.

Содержание 178AU27FHC

Страница 1: ...nd Freezers with Backsplash Commercial Refrigerator And Freezer User s Manual 1 User Manual Please read the manual thoroughly prior to equipment set up operation and maintenance 08 2022 178AU27FHC 178...

Страница 2: ...IGORIG NE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION D...

Страница 3: ...all the unit in an indoor well ventilated area For best performance please maintain clearance of 4 on the back of the unit Brackets should be attached on the back of the unit Outdoor use may cause dec...

Страница 4: ...frigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freezers are set to cycle between a minimum temperature of 5 degr...

Страница 5: ...es at preset intervals However if you would like to run a manual defrost cycle at any time please follow the steps below Freezers Press the defrost button def and down arrow for approximately 5 second...

Страница 6: ...east 10 minutes before plugging it back in Failure to do so could cause damage to the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands Dur...

Страница 7: ...and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning The Interior of Unit When cleaning the cabinet interior use a solvent of...

Страница 8: ...sket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make...

Отзывы: