Installation

Important!!! Please Read Before Installation

•  If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet to 

promote proper air flow.  Failure to install the shelves properly is considered user-error and is not 
covered by warranty.

•  If the unit has recently been transported on its side, please let unit stand still for a minimum of 24 

hours before plugging it in.

•  Make sure that the unit drops down to desired temperature before loading the unit with product.
• Make sure that there is proper ventilation around the unit in the area where it will operate.
• Make sure all accessories are installed (i.e.. Shelves, shelf clips, casters) before plugging the unit in.
• Please read through the manual in its entirety. 

 Cabinet Location Guidelines

•  Install the unit on strong and leveled surfaces

- Unit may be noisy and/or malfunction if surface is uneven.

•  Install the unit in an indoor, well-ventilated area

- For best performance, please maintain clearance of 4” on the back of the unit. Brackets should be attached on the 
back of the unit. 
- Outdoor use may cause decreased efficiency and damage to the unit.

• Avoid installation in a high humidity and/or dusty area

- Humidity could cause unit to rust and decrease efficiency of the unit.
-  Dust collected on condenser coil will cause unit to malfunction.
- Malfunction due to dirty condenser will void warranty.

•  Select a location away from heat and moisture-generating equipment

-  High ambient temperatures will cause the compressor to overwork, leading to higher energy bills and gradual 

breakdown of the unit. 

- The unit should not be used in areas over 90 degrees. 
- Malfunction due to high ambient temperature will void warranty.

•  For optimal performance, 3” of clearance is required around all louvered or vented panels, to allow 

for proper air flow

-For your convenience, a set of brackets is included to prevent this unit from being pushed up against a wall
-Component failure due to improper installation is not covered under warranty. 

Содержание 178AU27FHC

Страница 1: ...nd Freezers with Backsplash Commercial Refrigerator And Freezer User s Manual 1 User Manual Please read the manual thoroughly prior to equipment set up operation and maintenance 08 2022 178AU27FHC 178...

Страница 2: ...IGORIG NE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION D...

Страница 3: ...all the unit in an indoor well ventilated area For best performance please maintain clearance of 4 on the back of the unit Brackets should be attached on the back of the unit Outdoor use may cause dec...

Страница 4: ...frigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freezers are set to cycle between a minimum temperature of 5 degr...

Страница 5: ...es at preset intervals However if you would like to run a manual defrost cycle at any time please follow the steps below Freezers Press the defrost button def and down arrow for approximately 5 second...

Страница 6: ...east 10 minutes before plugging it back in Failure to do so could cause damage to the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands Dur...

Страница 7: ...and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning The Interior of Unit When cleaning the cabinet interior use a solvent of...

Страница 8: ...sket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make...