User Manual
16
2. Adjust pilot key to provide properly
sized flame as shown in diagram B.
Diagram A shows improperly adjusted
pilot.
3. Release pilot adjustment cap.
User Manual
www.AvantcoEquipment.com
5
E
NTREE
F
RYERS
S
ERVICE
E
NTREE
O
PERATOR
’
S
M
ANUAL
#400024
P
AGE
15
CHECKING AND ADJUSTING AUTO SAFETY PILOT
The pilot flame should surround the thermopile for 1/2". It must be large and sharp enough to cause the
thermopile to glow a dull red, or sufficient to hold the safety valve open.
1. Remove pilot adjustment cap
2. Adjust pilot key to provide properly
sized flame shown in diagram B.
Diagram A shows an improperly
adjusted pilot
3. Replace pilot adjustment cap.
TROUBLESHOOTING
NOTE: Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may
cause Hi-Limit Control Switch to open. If this condition persists, additional cushioning may be added to the
rubber grommets supporting this control to absorb these shocks.
Checking and Adjusting Safety Pilot
1. Remove pilot adjustment cap.
The pilot flame should surround the thermopile for 1/2". It must be large and sharp enough to cause the thermopile to
glow a dull red, or sufficient to hold the safety valve open.
Содержание 177FF300L
Страница 17: ...User Manual 17 Wiring Diagram...