User Manual
www.AvantcoEquipment.com
5
INSTALLATION
Do not use the door or its handle to lift the fryer.
Before installing the fryer, verify that the type of gas (natural or propane) is in conformity to the
specifications on the fryer data plate, which is located on the inside of the door panel. Make sure
the fryer is configured for the proper elevation.
Clearances
• Minimum clearance from combustible construction:
The fryer may be installed on combustible floors
Location
• Install fryer in an area with sufficient air supply for gas combustion at fryer burners.
• Do not obstruct the flow of combustion and ventilation air.
• Provide adequate clearance for air openings into the combustion chamber.
• Do not permit fans to blow directly onto fryer.
• Avoid wall-type fans, which create cross-currents within a room. Avoid open windows
next to sides or back.
Minimum clearance from
noncombustible construction
Sides of Fryer
Front of Fryer
Between the fryer and
any open-top flame units
16" (41 cm)
0"
0"
Minimum clearance from
noncombustible construction
Sides of Fryer
Back of Fryer
6"
6"
Allow space for
servicing and operation.
NOTE
All avantco donut fryers shall be installed with at least a 16
inch space between the fryer and Surface flames from
adjacent equipment