Installation (for qualified installers only)
9
© Travis Industries
4151204
100-01430
Factory-Built (Metal) Wood-Burning Fireplace Requirements
NOTE
:
Any parts that are removed must be removed in a way that would allow them to be re-
installed if the insert is ever removed (removal of rivets or screws is acceptable).
The damper ("A") and grate (with log set) ("B") must be removed (see the illustration below)
The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and
metal or glass doors ("F") may be removed (if applicable)
The fireplace must be permanently marked to
indicate that it has been altered and is no longer
suitable for burning solid fuel (wood), unless the
removed parts are re-installed. Cutting of any
sheet metal parts is prohibited.
The insulation ("H"), and any structured rigid frame
members must not be removed or altered (side and
top of door frame, side and top of the face of the
fireplace, metal sides, etc.).
The metal floor (“J”) of the firebox may be removed
in certain cases*.
The surround panels should not seal ventilation
openings on the fireplace.
*CAUTION:
Firebox floor removal is not covered under the appliance safety standard (ANSI
Z21.88 CSA 2.33
)
used in the safety certification of this appliance. The safety certification does not apply to this method of
installation. Before installing the appliance using this method, contact the Authority Having Jurisdiction to
determine if this installation is acceptable in your area. The sheet metal base of the fireplace must be left in
place.
If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5 mm) or
less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner.
This access hole must be plugged with non-combustible insulation after the gas supply line has been
installed.
Hearth Requirements
The heater and face must not contact combustible surfaces. A non-combustible hearth extension is
not required. However, if the heater is installed next to the floor, we recommend a hearth to protect
the flooring surface from discoloration or other negative impact from the heater.
C
B
F
I
D
E
A
G
H
J
Содержание Radiant Plus Small Insert
Страница 32: ...32 Operation Travis Industries 4151204 100 01430 Remote Control Operation ...
Страница 33: ...Operation 33 Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Страница 34: ...34 Operation Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Страница 35: ...Operation 35 Travis Industries 4151204 100 01430 Remote Control Operation continued ...