Optional Equipment
33
Travis Industries
4 1 2 2 1 0 4
9 3 5 0 8 1 1 7
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
off the pilot
assembly.
5/32" Hex
Use a hex wrench to
unscrew the orifice.
Remove the orifice and replace with the LP orifice. Screw the
orifice all the way in and replace the pilot hood.
LP (Propane) Orifice
Orifice Identification:
NG (Natural Gas) Orifice
35
62
35
a
b
c
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
5
Install the logs and embers.
6
Close door.
7
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
A
A
b
Place the LP label on the access
panel near the gas control valve.
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Remove and discard the
regulator, diaphram, spring
and center post.
Slotted
Screwdriver
(or T-20 Torx)
c
d
Open the this panel covering the gas control valve.
a
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
e
Содержание 93508117
Страница 2: ......