8
Installation
(for qualified installers only)
Travis Industries
4 1 2 2 1 0 4
9 3 5 0 8 1 1 7
Vent Requirements
!
Always maintain the required 1” clearance (air space) to combustible materials to prevent a fire hazard.
Do not fill air spaces with insulation.
!
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it’s own separate vent system.
•
This appliance is equipped only for
altitudes 0-2000 feet. However, our
in-house testing has shown that the
unit operated at altitudes to 8000 ft.
!
Failure to adjust the air shutter
properly may lead to improper
combustion which can create a safety
hazard. Consult your dealer or
installer if you suspect an improperly
adjusted air shutter.
•
When the vent passes through a wall,
a wall thimble is required. When the
vent passes through a ceiling, a
support box or firestop is required.
When the vent passes through the
roof, a roof flashing and storm collar
are required. Follow the instructions
provided with the vent for installing
these items.
Use a firestop spacer whenever
passing through a ceiling
(Duravent Part #963)
Vertical Termination
(Duravent Part # 991)
Use a roof flashing and storm collar
whenever passing through the roof
(Duravent Part #953 & #943 or #943S)
8-5/8"
Use a support box
on exposed vent
Vertical Vent
Requirements
Use a wall thimble
whenever passing
through a wall
(Duravent Part #942)
Horizontal Termination
(Duravent Part #984)
Maintain a minimum 1" clearance
from vent to any combustible
(vent is 6 5/8" diameter)
Minimum
Framing for
wall thimble
Horizontal Vent
Requirements
Minimum framing
for fire stop
8-5/8"
Maintain a minimum 1"
clearance from vent to
any combustible (vent
is 6 5/8" diameter)
•
Use one of the following 6-5/8" diameter co-axial gas direct vent systems:
Manuafacturer
S e r i e s
Simpson Dura-Vent
Model GS
Selkirk Hearth Products
Direct-Temp
American Metal Products
Ameri-Vent
N O T E
: Always use the high-wind cap for the type of vent you are using (if applicable)
•
Slide the vent sections together and turn 1/4 turn until the sections lock in place.
•
Screws are not required to secure the vent. However, three screws may be used to
secure vent sections together if desired.
•
High temperature sealant is recommended at the appliance starter section connection
(use high-temperature silicone or Mill-Pac®).
•
If disassembly is required, at time of re-assembly check to see if the vent creates a tight
fit. If it does not, apply high temperature sealant to the joints of the affected sections.
•
Horizontal sections require a 1/4" rise every 12" of travel
•
Horizontal sections require non-combustible support every three feet (e.g.: plumbing
tape)