APX-3302 User's Manual (OM110000019A)
-15 -
3.1.1 SW1 setting
SW1 should be used in OFF anytime.
3.1.2 SW2 setting
SW2 sets up Pull-Up as a general-purpose output.
C
ut
Pull-Up resistor off by OFF then connect Pull up by ON
Pull-Up resistor:
330Ω
The relation between the switch and signals is shown below
Figure3-2: SW2 setting
SW2 is set as OFF, all Pull-up resistors are separated and are set as the open collector output in
default setting.
3.1.3 SW3 setting
SW3 should be used in OFF anytime.
3.1.4 CN7, CN8 setting
Set up the validity or invalidity of PoCL function according to the channel of camera.
PoCL is valid in ON and is invalid in OFF.
CN7 corresponds to ch1 of camera and CN8 corresponds to ch2 of camera.
Figure3-3: CN7, CN8 setting
CN7 and CN8 are set as ON and PoCL function is valid in default setting.
* In order to use a PoCL function, it is necessary to control feeding power not only by this setting but also by
software. Refer to [
6.2 Power over CameraLink
]
for the details.
1
2
3
4
O
N
SW2
SW2-1: General-purpose output -1 GP_OUT1
SW2-2: Reserved General-purpose output-1 OUT_RES1
SW2-3: General-purpose output -2 GP_OUT2
SW2-4: (Unused)
SW2-3 : (intact)
SW2-4 : (intact)
CN7/CN8
1
3
OFF
ON
Содержание APX-3302