APX-3302 User's Manual (OM110000019A)
-46 -
The invalid sequence under turning on electricity is as follows.
Power ON
Stop Clock Output
+12V
Cameralink Clock
Clock Detect Flag
Toff
If it cannot detect clock detect flag within the set time of Toff,
"Power OFF Error" will occur and stop power supply.
Stop Power Supply
Figure6-7: The invalid sequence under turning on electricity
■
The setting example for software
The sample code which performs to supply 1ch side camera and to configure the set time as 3000ms is as
follows.
Note: Supplying control is possible only when setting of the jumper (CN7/CN8) of APX-3302 is ON.
For more information of the jumper setting, refer to [
3.1.4 CN7, CN8 setting
].
<Sample code>
// Clear error status of camera power supplying
AcapSetInfo(hDev, INPUT_CH, ACL_POWER_STATE, 0, 1)
// Begin power supplying to camera
AcapSetInfo(hDev, INPUT_CH, ACL_POWER_SUPPLY, 3000, 1)
Содержание APX-3302
Страница 1: ...APX 3302 User s Manual ...