Avacom NAPB-A070-012 Скачать руководство пользователя страница 6

3

CHARGER FEATURES

ź

Intelligent charging modes.

ź

The built-in microprocessor that continuously monitors a battery condition and automatically provides 
the optimum voltage and the current to the charged battery.

ź

The memory function that keeps the charger in the mode which was set the last time.

ź

The regeneration mode for a deeply discharged battery.

ź

Several charging modes ensure the economical charging according an actual battery status and 
battery type. When the battery is fully charged the charger will switch to the maintenance charging 
mode.

ź

Compact size and light weight.

CHARGERS SAFETY FEATURES

ź

Electronic protection does not allow damaging the charger in case of short circuit or excessive load.

ź

The battery protection prevents damaging of charger and battery, if positive and negative poles were 
connected incorrectly.

ź

The protection which prevents damage to sensitive electronic components.

ź

Thermal protection which prevents damage of charger in the case of excessive temperatures during 
the charging process.

ź

IP65 protection prevents intrusion of dust and water into the charger.

DESCRIPTION OF LED INDICATORS AND BUTTONS

2

1

LED charge level indicator. LED indicator lit up - battery capacity is 0% - 25%.

2

LED charge level indicator. LED indicator lit up - battery capacity is 25% - 50 %.

3

LED charge level indicator. LED indicator lit up - battery capacity is 50% and above.

4

LED charge level indicator. LED indicator lit up - battery capacity is fully charged.

5

LED indicator of short circuit. LED indicator lit up - electric circuit is shorted.

!

6

LED indicator of reversed terminals. LED indicator lit up - terminals are reversed.

7

LED indicator of damaged batteries. LED indicator lit up - battery is damaged.

8

LED power indicator. LED indicator lit up - charger is plugged in.

9

Summer mode. The maximum voltage 14.4V - 7A. Suitable for charging 12V lead-acid 
batteries at normal temperatures.

10

Winter mode. The maximum voltage 14.7V - 7A. Suitable for charging 12V lead-acid 
batteries at low temperatures. Recommended for AGM batteries.

11

Turbo mode. The maximum voltage 16V - 7A. Suitable for charging 12V lead-acid batteries containing 
calcium and charging for deeply discharged batteries, which is caused by acid stratification.

12

Button for setting charging modes.

POWER

CHARGING

ź

First, make sure the voltage of lead acid batteries you want to charge is 12V.

ź

Disconnect the battery from its operational load. If the battery is installed in the vehicle, turn the ignition 
off as well as other devices connected to the battery. Follow the safety instructions of the vehicle 
manufacturer. Modern vehicles are equipped by sensitive electronic components and controls that can 
be damaged if you don’t strictly follow the instructions of the vehicle manufacturer.

ź

Plug the charger into the electrical outlet (220V - 240V ~50Hz/60Hz).

ź

Connect the red clip to the positive (+) terminal of the battery. Connect the black clip to the negative (-) 
terminal of the battery.

ź

If the electric circuit is shorted the LED indicator 

 will light up.

ź

If positive and negative terminals are reversed the LED indicator 

 will light up.

ź

If the battery is damaged the LED indicator 

 will light up.

ź

The charger has a memory function. After connecting to the outlet it’s in the mode that was set the last 
time.

ź

Now you can now select the operating mode by pressing the button 

, see below.

OPERATING MODES

 SUMMER MODE (MAXIMUM CHARGING VOLTAGE 14.4V ± 0.25V, 7A).

ź

This mode is suitable for lead-acid and gel batteries with a capacity above of 14Ah at normal ambient 
temperatures environment.

ź

To select this mode, press down the button 

 until the LED indicator 

 lights up. After the 

indicator lit up the charger will automatically start charging.

ź

When the battery is fully charged, the LED indicator 

 will light up and the charger will automatically 

switch to the maintenance charge mode.

 WINTER MODE (MAXIMUM CHARGING VOLTAGE 14.7V ± 0.25V, 7A).

ź

This mode is suitable for AGM batteries and gel batteries with a capacity above 14Ah at low ambient 
temperatures.

ź

To select this mode, press down the button 

 until the LED indicator 

 lights up. After the 

indicator lit up the charger will automatically start charging.

!

POWER

BOOST

BATTERY CHARGER

12V - 7A

MODE

!

1

9

11

2

7

3

6

12

4

8

10

5

Содержание NAPB-A070-012

Страница 1: ...do nabíječky červený konektor plus černý konektor mínus ź Dodržujte všechny bezpečnostní pokyny výrobce akumulátoru Akumulátory nikdy nerozebírejte ź Olověné akumulátory obsahují agresivní kyseliny Vyhněte se kontaktu s pokožkou nebo očima Při kontaktu s pokožkou důkladně omyjte postižené oblasti vodou a mýdlem Při zasažení očí je ihned vypláchněte studenou tekoucí vodou Oční víčka rozevřete třeba...

Страница 2: ...nkcí Po zapojení do elektrické sítě je nabíječka automaticky v režimu který byl nastaven naposledy ź Funkce regenerace akumulátoru Nabíječka po napojení na akumulátor automaticky pozná že akumulátor je hluboce vybitý a začne akumulátor nejprve nabíjet pomocí nižšího proudu Jakmile akumulátor dosáhne optimálního napětí nabíječka pokračuje v dobíjení standardním způsobem ź Několik režimů nabíjení um...

Страница 3: ...onektor plus čierny konektor mínus ź Dodržujte všetky bezpečnostné pokyny výrobcu akumulátora Akumulátory nikdy nerozoberajte ź Olovené akumulátory obsahujú agresívne kyseliny Vyhnite sa kontaktu s pokožkou alebo očami Pri kontakte s pokožkou dôkladne umyte postihnuté oblasti vodou a mydlom Pri zasiahnutí očí ich ihneď vypláchnite studenou tečúcou vodou Očné viečka roztvorte napríklad aj násilím a...

Страница 4: ...ovou funkciou Po zapojení do elektrickej siete je nabíjačka automaticky v režime ktorý bol nastavený naposledy ź Funkcia regenerácie akumulátora Nabíjačka po napojení na akumulátor automaticky spozná že akumulátor je hlboko vybitý a začne akumulátor najprv nabíjať pomocou nižšieho prúdu Akonáhle akumulátor dosiahne optimálneho napätia nabíjačka pokračuje v dobíjaní štandardným spôsobom ź Niekoľko ...

Страница 5: ...m the rechargeable battery first and only then the positive terminal Ensure the correct polarity when connecting batteries to the charger red terminal of the charger plus black terminal of the charger minus ź Follow strictly all safety instructions given by battery manufacturer Never disassemble the battery ź Lead acid batteries contain corrosive acids Avoid contact with eyes or skin After contact...

Страница 6: ...ed for AGM batteries 11 Turbo mode The maximum voltage 16V 7A Suitable for charging 12V lead acid batteries containing calcium and charging for deeply discharged batteries which is caused by acid stratification 12 Button for setting charging modes POWER CHARGING ź First make sure the voltage of lead acid batteries you want to charge is 12V ź Disconnect the battery from its operational load If the ...

Страница 7: ...eachten Sie die Polarität beim Anschluss der Batterie an das Ladegerät roter Ladeanschluss positiv schwarzer Ladeanschluss negativ ź Stellen Sie sicher dass Sie alle Sicherheitshinweise und Ladeanweisungen des Batterieherstellers beachten Zerlegen Sie niemals Bleibatterien ź Bleibatterien enthalten aggressive und korrosive Säuren Haut oder Augenkontakt mit Batterieflüssigkeit ist zu vermeiden Zerl...

Страница 8: ... der Akku eine normale Spannung erreicht wird das Ladegerät den Ladevorgang mit dem regelmäßigen Prozess fortsetzen ź Mehrere Ladebetriebsarten die wirtschaftliche Batterieladung je nach dem spezifischen Zustand und dem Typ der Batterie ermöglichen und vermindern maximal Wärmeverlust während des Ladevorgangs ź Energiesparende automatische Funktion die die Strommenge vermindert wenn der Akku vollst...