11.
AUTOMATIC FAST PACKAGING
COMMON USES FOR THE OPERATION BUTTON
This function can be applied to high-volume labels of similar but different weights for a product.
Procedure: Activate the
[AUTO PRN]
and
[PRI LOCK]
function. Choose a single product or enter
a unit price. Put the goods on the scale tray one by one, and the scale will start to print label
automatically. If you want to operate at a faster pace, follow the next procedure.
Procedure: Put item 1 on the scale tray, it will print label automatically. Put item 2 on and take off
item 1. Take the label and stick it on item 1. The next label will print automatically. Put item 3 on
and take off item 2. Take the label and stick it on item 2. The next label will print automatically.
Repeat the procedure to save time.
• Auto print: Switch to automatic print, otherwise you’ll need to press button
[PRN / ENTER]
to
print.
• Charge unit: Press button
[UNIT]
for 2 seconds to switch charge unit to kg or g.
• Price locking: Press button
[PRI LOCK]
to continuously print label of same product (product
name will not disappear). Press again to unlock.
• Price change: Press any hotkey and press button
[PRICE]
to input price.
• Discount: Enter the discount rate (Ex. enter 80 for 80% discount) and press button
[DISCOUNT]
to calculate. Enter hotkey of the goods put goods on the scale to start printing.
• Zero: Press button
[ZERO]
to zero out of all the data.
• Peeling/Tare: Press button
[TARE]
. Put goods on the scale, enter corresponding hotkey after
printing, press button
[TARE]
to clear the tare weight.
• Clear: This button is commonly used to clear the unit price and to keep the system running
normally.
• Setting: Press button
[SETTING]
and hold for 2 seconds to enter the setting interface, where
you can reset basic settings and parameters of the printer and scale, such as IP setting, restore
factory setting, print barcode type setting, WIFI setting, etc. Press
[↑] [↓]
button to select
function setting, press button
[PRN / ENTER]
to enter setting interface, then set it.
•
NOTE:
If the wrong operation causes the system to crash, restart the scale.