AUX Air Conditioner Service manual
21
Press the button again. the air-conditioner stops.
Remark: In the circulation operation mode. to set the temperature is noneffective.
★
Automatic operation mode
1. Press the MODE button. select the automatic operation mode.
2. Press the “ FAN ” button. you can select fan speed.
The type of H
、
M series:
You can select fan speed from “Power”. “High”. “Low”. “Mute”.
The type of E series:
You can select fan speed from “Auto”. “High”. “Mid”. “Low”.
3. Press the “ ” button. the operation indicator is on. the air-conditioner starts to operate the
Automatic mode.
Press the button again. the air-conditioner stops.
Remark: In the automatic operation mode. to set the temperature is noneffective.
★
Clock time setting
1. Pressing the TIMER/CLOCK button for 5 seconds. the time indicator at present begins to glimmer.
2. Adjust present time through pressing the
or
button.
3. Pressing the TIMER/CLOCK button once again. the time setting is finished.
Remark: Time can be regulated only after the timing mode is cancelled.
★
Timer setting
☆
Set the “ Timer ON ” ( It is effective only when the air conditioner is shut off ).
1. Press the TIMER/CLOCK button. the remote controller display “
” intermittently.
2. Adjust time through pressing the
or
button.
3. Press the TIMER/CLOCK button once again. the “ Timer ON ” setting is finished.
☆
Set the “ Timer OFF ” ( It is effective only when the air conditioner is running ).
1. Press the TIMER/CLOCK button. the remote controller display “
” intermittently.
2. Adjust time through pressing the
or
button.
3. Press the TIMER/CLOCK button once again. the “ Timer OFF ” setting is finished.
★
Sleeping operation mode
1. Press the “ SLEEP ” button. the sleeping indicator light of indoor unit flashes on.
2. After the setting of sleeping mode. the cooling operation enables the set temperature to increase 1
℃
after 1 hour and another 1
℃
automatically after 1 hour.
3. After the setting of sleeping mode. the heating operation enables the set temperature to drop 2
℃
after 1 hour and another 2
℃
automatically after 1 hour.
4. The air-conditioner runs in sleeping mode for 7 hours and stops automatically.
Remark: Press the MODE button or ON/OFF button. the remote controller clears sleeping mode
away.
Содержание EA Series
Страница 1: ...AUX One to Two Split Air Conditioner Service Manual EA EL HS Series ...
Страница 48: ...AUX Air Conditioner Service manual 46 9 Fault analysis of major parts ...
Страница 58: ...AUX Air Conditioner Service manual 56 b Single Cooling Model ...
Страница 59: ...3 Wiring diagram for Original Multi type a Indoor unit Wiring diagram b Outdoor unit Wiring diagram 57 ...
Страница 60: ...AUX Air Conditioner Service manual 57 Section 10 Service Record Date Page Part Cause Report ...