will be screened. Under the mode of heating, when the
compressor is powered on, indoor fan will be started after 30
seconds’ delay with the wind speed as set while when
compressor is powered off, indoor fan will be turned off after 30
seconds’ delay and the related breakdown can be indicated at the
same time.
10.4.3 When it is detected that the T external coiled pipe signal sent
by outdoor coiled pipe temperature sensor is abnormal, the air
conditioner will work for 50 minutes, defrost for 10 minutes and
heat in cycles if the signal received from remote control is
“heating” and the related breakdown can be indicated at the
same time while the air conditioner will not be powered off and
will operate normally if the signal received from remote control
is heating or defrosting or ventilation and the related breakdown
can be indicated at the same time.
10.5 disposal of indoor PG electric motor abnormity
When indoor PG electric motor is loaded with voltage, the indoor
fan will operate under the mode of “weak wind” automatically if
the pulse signal feed backed by the indoor electric motor is not
detected within 12 seconds. If the feedback signal detected is
normal, the indoor fan will resume the turning speed set and the
related breakdown indication will be disappear.
Содержание ASW-07B4/HSAR
Страница 1: ......
Страница 7: ...Operation Hints ...
Страница 8: ......
Страница 9: ......
Страница 33: ......
Страница 35: ...Chapter 5 Main Technical Data ...
Страница 42: ...4 To remove the axial flow fan and fan motor 5 To remove the electric assembly ...
Страница 61: ...Operation Hints ...
Страница 62: ......
Страница 63: ......
Страница 93: ...4 To remove the axial flow fan and fan motor 5 To remove the electric assembly ...
Страница 112: ...6 60 detachable cool warm type 70 detachable cool warm type ...
Страница 113: ...7 Operation Hints ...
Страница 114: ...8 ...
Страница 146: ...40 4 To remove the axial flow fan and fan motor 5 To remove the electric assembly ...