7. Trouble shootings
7. Trouble shootings
7. Trouble shootings
7. Trouble shootings
Step
Phenomenon
Reason
Remedy
1
Power lamp is not
turned on when power
switch is ON.
Poor lamp
Replace lamp
Poor contact of the 1st input part
Contact test
Poor fuse
Replace fuse
Poor NFB
Replace NFB
2
Only FAN works.
Poor torch switch
Replace torch switch
Power lamp is on, but
fan does not work.
Poor fan motor
Replace fan motor
3
Gas doesn' t come out.
No gas or no connection
Check and replace
Poor solenoid valve
Replace valve
Defect in control PCB
Request A/ S
Poor torch switch
Replace torch switch
4
Gas comes out
continuously.
Gas comes out even if power is off.
Remove foreign
material from valve
Poor solenoid valve
Replace valve
Defect in control PCB
Request A/ S
Poor torch switch
Replace torch switch
5
Weld wire is not fed
even though inching
switch is pressed.
Poor motor fuse
Replace fuse
Poor motor
Replace motor
Poor PCB relay
Replace relay
Wire is not fed when
torch switch is ON.
Poor torch switch
Replace torch switch
Poor PCB
Request A/ S
6
Voltage and current are
not adjustable.
Poor remote contact
Check and replace
Poor control volume
Replace
Poor PCB
Request A/ S
7
Under no- load
condition, voltage meter
does not work and no
ARC.
Poor torch switch
Replace torch switch
Poor PCB
Request A/ S
Under no- load
condition, voltage meter
works but no arc.
Broken torch cable
Replace torch cable
Poor contact of earth able
Check
8
Crater is not
controllable.
Poor control volume
Replace
Poor PCB
Request A/ S