9
Be sure that the drain line remains unrestricted so that
regeneration water and brine can flow freely to the
drain. Do not set objects on the drain line that could
crimp the line and restrict flow.
Manual Valve Operation
Manual Valve Operation
Manual Valve Operation
Manual Valve Operation
The camshaft may be rotated manually to actuate the
valve functions for service purposes.
1. Unplug the wall-mount transformer.
2. Remove the rear cover by pulling back on the tab
provided on the cover. Next, lift the rear cover off
the valve, Figure 2.
3. Rotate the camshaft COUNTERCLOCKWISE until
the appropriate valve is opened by the camshaft
lobe. Use the regeneration cycle indicator as a
guide to which valve discs are open.
4. When the service is complete, rotate the camshaft
so the regeneration cycle indicator is pointing to
the end of the refill cycle.
5. Reinstall cover, reconnect electric power, and reset
the time of day.
6. The display will show Err3 and the motor will start
up. After approximately five minutes, the indicator
will point to REGENERATION COMPLETE and the
control starts alternating the display between TIME
OF DAY and CAPACITY.
7. The conditioner is now in operation.
Additional Features
Additional Features
Additional Features
Additional Features
When your dealer installs the conditioner, the control
settings are adjusted to meet your soft water needs.
However, there are additional features which your
dealer can incorporate into the control. These features
are 12- or 24-hour clock, U.S. or metric units of
measure, Calendar Override and Immediate
Regeneration.
12 or 24-Hour Clock
The standard clock is a 12-hour with a p.m. indicator.
An optional 24-hour clock without a p.m. indicator is
available. Time can be set from 00:00 to 23:59. This
option applies to both the Time of Day and Time of
Regeneration settings.
U.S. or Metric Units of Measure
The standard units of measure are U.S. values.
Hardness is in grains per gallon, salt is in pounds, and
capacity is in kilograins. The metric option changes
these to milligrams per liter, kilograins to kilograms
respectively. All control settings use the metric values
when the metric option is selected.
Calendar Override
The Calendar Override option is a method of forcing the
control to regenerate after a preset number of days, if a
normal demand-based regeneration does not occur
first. This feature is not set at the factory; your dealer
can set it at one to 30 days.
Immediate Regeneration
The control is factory set to wait until the Time of Day
reaches the Time of Regeneration to begin a
regeneration. Your dealer can program the control to
regenerate any time the capacity remaining reaches
zero. Remember that you do not have soft water
available during any regeneration.
Disinfection of Water Conditioners
Disinfection of Water Conditioners
Disinfection of Water Conditioners
Disinfection of Water Conditioners
The construction materials of the water conditioning
system do not support bacterial growth or contaminate
the water supply. However, we recommend that your
conditioner be disinfected after installation and before
the conditioner is used to treat potable water. In
addition, a conditioner can become fouled with organic
matter during normal usage or with bacteria from the
water supply. Periodic disinfection is recommended for
all conditioners.
Use one of the following methods of disinfection based
on operating conditions, style of conditioner, type of ion
exchanger, and disinfectant available.
Sodium Hypochlorite
Sodium hypochlorite, 5.25% solutions, can be used
with polystyrene resin, synthetic gel zeolite, greensand,
and bentonites and are available under trade names
such as Clorox, Linco, Bo Peep, White Sail, and Eagle
Brand Bleach.
The recommended dosage for 5.25% solutions is:
•
Polystyrene resin: 1.2 fluid ounces per cubic foot
•
Non-resinous exchangers: 0.8 fluid ounce per
cubic foot
Calcium Hypochlorite
Calcium hypochlorite, 70% available chlorine, is
available in several forms including tablets and
granules. These solid materials can be used directly
without dissolving before application. The
recommended dosage for calcium hypochlorite is two
grains (approximately 0.1 ounce) per cubic foot.
Complete the following steps to disinfect the
conditioner:
1. Add the disinfectant to the brine well of the brine
tank. Make sure that the brine tank has water in it so
the solution is carried into the conditioner.
2. Press the REGEN button.