7
Complete the following steps to change the Capacity
Setting; refer to Table 1:
1. Press the down arrow [
↓
] button until the green light
next to the CAPACITY legend is on. The setting
range is 0.1 to 140.0 kilograins (0.1 to 14.00
kilograms for metric).
2. Press the SET button and the first number starts
flashing. If you want to change this number, press
the up arrow [
↑
] button to increase the number or
the down arrow [
↓
] button to decrease the number.
To skip the number without changing, press the left
arrow [
←
] button.
3. When the number is correct, press the left arrow
[
←
] button. The first number stops flashing and the
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the SET button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts
alternating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
Reminder:
Whenever the HARDNESS or CAPACITY
setting is changed, you should regenerate the
conditioner by pressing the REGEN button.
If the control does not display the Capacity Setting,
your dealer has disabled it. Some municipalities require
that the Salt Setting be disabled, which also disables
the Capacity Setting. Contact your dealer for additional
information.
Water Conditioner Regeneration
Water Conditioner Regeneration
Water Conditioner Regeneration
Water Conditioner Regeneration
Your water conditioner regenerates for one of two
reasons:
•
The control determines that the conditioner
does not have enough capacity remaining to
satisfy your soft water needs for the next day.
•
The REGEN button was pressed.
In either case, the REGENERATION INDICATOR makes
one complete counterclockwise rotation and returns to
REGENERATION COMPLETE. The indicator pauses at
some or all of the different positions shown on the label
around the indicator. The display alternates between
TIME OF DAY and REGEN TIME REMAINING, as
indicated by the green lights next to the legends. Regen
Time Remaining is shown in minutes on the display.
When the indicator reaches REGENERATION
COMPLETE and the time remaining is zero, the
regeneration is complete, conditioned water is
available for use, and the control starts alternating the
display between TIME OF DAY and CAPACITY. No
settings can be changed during a regeneration.
The
settings can be viewed, but the control beeps and
ignores any attempt to change settings.
Automatic Regeneration
The control makes regeneration decisions based on the
amount of water that has flowed through the
conditioner. The control uses the Hardness and
Capacity settings to calculate the number of gallons
(cubic meters for metric) which can be conditioned. At
the Time of Regeneration, the control updates the
average usage for the previous day and adjusts the
reserve capacity accordingly. The reserve is kept at a
minimum for optimum economy. The control reacts to
a sudden increase in water usage. If a day’s usage is
more than double the current average, the control
anticipates that a second day of high usage is likely to
occur. The high usage amount is used as the reserve
when the control performs the regeneration
computation.
The Guest Cycle option and the Calendar Override
option may override this computation. Refer to the
Additional Features
section in this manual or contact
your dealer for more information about these options.
The factory setting for Time of Regeneration is
2:00 a.m. You can change this time. Refer to the Time
of
Regeneration section in this manual for additional
information.
Manual Regeneration
To force the control to perform a regeneration, press the
REGEN push button. This button is located on the front
of the control. When you press the REGEN button, the
control performs a full regeneration of the conditioner.
You can use this feature if you need a large amount of
conditioned water but the capacity remaining is low.
Note:
If you press this button again a minute or more
after regeneration begins, a second regeneration will
start when the first regeneration is complete. The
display shows only the REGEN TIME REMAINING
information.
Care of Your Water Conditioner
Care of Your Water Conditioner
Care of Your Water Conditioner
Care of Your Water Conditioner
General
Check the salt level in the salt storage tank a few weeks
after installation and weekly after that. Always maintain
the salt level above the water level for a consistent salt
dosage and proper water conditioner operation. Don’t
allow the conditioner to run out of salt before refilling.
When filled, the salt storage tank contains enough salt
to support numerous resin bed regenerations. Use
pellet, block, or nugget water conditioner salt. Do not
Содержание 255-960
Страница 1: ...Water Conditioning Control System Operation and Maintenance Manual Series 255 Valve 960 Control...
Страница 8: ......
Страница 10: ......
Страница 14: ......
Страница 18: ...Copyright 2000 1999 Osmonics Printed in the USA P N 1017934 Rev C...