The front panel incorporates several important features 
which allow you to know the status of your water 
conditioner. These features are:

Regeneration Cycle Indicator.

 The white indicator 

points to the status of the conditioner. Soft water is 
available when the indicator points to 
REGENERATION COMPLETE. Other positions 
indicate that the conditioner is regenerating the 
resin bed and only hard water is available.

Four-Digit Display.

 The four-digit red LED display 

shows system information such as time of day, 
gallons of conditioned water available, time the 
conditioner will regenerate, or any error alarms.

Green Indicator Lights.

 The green indicator lights 

are located at the right of the control panel.

TIME OF DAY

TIME OF REGEN

HARDNESS

SALT AMOUNT

CAPACITY 

REGEN TIME REMAINING

When a green light is on next to one of the six control 
legends, the LED display provides information 
pertaining to that legend. When conditioned water is 
available, the display alternates between TIME OF DAY 
and CAPACITY and the corresponding green lights 
alternate between these control legends.

Programming Push Buttons.

 The programming 

buttons are located at the bottom of the panel 
under the display. Use the buttons to look at or 
change the conditioner settings.

REGEN Push Button. 

The REGEN button is 

located at the bottom of the panel below the six 
indicator lights. Press the button to start a 
regeneration of the water conditioner.

Note:

 If you press the button again a minute or more 

after regeneration begins, a second regeneration will 
start when the first regeneration is complete. The 
display freezes with the REGEN TIME REMAINING 
information. After the first regeneration is complete, the 
second regeneration begins immediately. The display 
will alternate between the TIME OF DAY and REGEN 
TIME REMAINING.

Control Settings

Control Settings

Control Settings

Control Settings

General Information

Use the four programming push buttons to change any 
of the control settings. Settings can only be changed if 
the regeneration cycle indicator is pointing at 
REGENERATION COMPLETE. If you try to change a 
setting when the cycle indicator is in any other position 
or if the setting is not valid, the control beeps to let you 
know that the new setting has been ignored.

To change a setting:

 Press the down arrow [

] button 

until the green light is illuminated next to the control 
setting you want to change. That control setting value 
shows on the display. Press the SET button and the far 
right number on the display starts flashing. If you want 
to change the number, press the up arrow [

] button to 

increase the number or the down arrow [

] button to 

decrease the number. To skip the number without 
changing, press the left arrow [

] button.

Note:

 If you press and hold either the up arrow [

button or the down arrow [

] button for more than one 

second, the flashing number will scroll up or down.

When the number is correct, press the left arrow [

button. The first number stops flashing and the next 
number starts flashing. You can only change the 
flashing number. Continue changing numbers until you 
reach the desired setting. Press the SET button. The 
numbers stop flashing and the control accepts the new 
setting. After approximately 30 seconds, the control 
starts alternating the display between TIME OF DAY 
and CAPACITY.

Note:

 If a beep sounds, the new setting is not accepted 

because it was outside the range of allowable values. 
The old setting will be shown on the display.

Time of Day Clock

The control uses the Time of Day clock and the amount 
of conditioned water remaining to decide when to 
begin a regeneration. When a regeneration is necessary 
and the Time of Day clock is at the same time as the 
Time of Regeneration setting, the control starts the 
regeneration.

When the green light is on next to the TIME OF DAY 
legend, the display is showing the time that the control 
thinks is correct. If you need to change the Time of Day, 
refer to the instructions later in this section. The Time of 
Day displays time in hours and minutes separated by a 
colon[:]. When the colon is flashing on and off, water is 
flowing through the conditioner. There is a small red dot 
in the upper left corner near the p.m. letters to indicate 
p.m. for 12-hour clocks. When the dot is off, the time is 
a.m. You can set the clock for any time, a.m. or p.m.

Complete the following steps to change the Time of 
Day:

1. Press the down arrow [

] button until the green light 

next to the TIME OF DAY legend is on.

2. Press the SET button and the minute number on 

the display starts flashing. If you want to change 
this number, press the up arrow [

] button to 

increase the number or the down arrow [

] button 

to decrease the number. To skip the number 
without changing, press the left arrow [

] button.

3. When the number is correct, press the left arrow 

[

] button. The first number stops flashing and the 

Содержание 255-960

Страница 1: ...Water Conditioning Control System Operation and Maintenance Manual Series 255 Valve 960 Control...

Страница 2: ...ration Manual Regeneration Care of Your Water Conditioner 7 General Cleaning the Injector Injector Screen Maintaining the Drain Line Manual Valve Operation 9 Additional Features 9 Disinfection of Wate...

Страница 3: ...tating turbine that measures water usage Time and Capacity Display During normal conditioning operation the correct time of day alternates with capacity on the display The capacity value is the number...

Страница 4: ...until the green light is illuminated next to the control setting you want to change That control setting value shows on the display Press the SET button and the far right number on the display starts...

Страница 5: ...er stops flashing and the next number starts flashing You can only change the flashing number 4 Continue changing numbers until you reach the desired setting 5 Press the SET button The number stops fl...

Страница 6: ...s flashing You can only change the flashing number 4 Continue changing numbers until you reach the desired setting 5 Press the SET button The number stops flashing and the control accepts the new sett...

Страница 7: ...l starts alternating the display between TIME OF DAY and CAPACITY No settings can be changed during a regeneration The settings can be viewed but the control beeps and ignores any attempt to change se...

Страница 8: ......

Страница 9: ...the metric values when the metric option is selected Calendar Override The Calendar Override option is a method of forcing the control to regenerate after a preset number of days if a normal demand b...

Страница 10: ......

Страница 11: ...1 6 Drain Control Assembly w O Rings 1 13 1031402 Locking Bar English Language 1 1034162 No 6 for 6 inch Diameter Tank 14 1006093 Screw No 8 x 9 16 inch 1 1000209 No 7 for 7 inch Diameter Tank 15 100...

Страница 12: ...r Bypass Valve and Piping Boss Meter Adapter Bypass Valve and Piping Boss Meter Adapter Bypass Valve and Piping Boss BYPASS BYPASS Bypass Valve Piping Boss Meter Adapter 960 Control Wall Mount Transfo...

Страница 13: ...pter Kit 1 1040284 1 inch BSPT Noryl 1001614 1 inch CPVC Tube Adapter Kit 1 2 1040339 Installation Kit Piping Boss 1001615 25 mm CPVC Tube Adapter Kit 1 1001408 Elbow Adapter 1001769 3 4 inch NPT Plas...

Страница 14: ......

Страница 15: ...act dealer c Contact dealer Loss of power to the system a Transformer unplugged b Fuse blown circuit breaker open or circuit switched off a Connect power b Correct the electrical problem Control does...

Страница 16: ...sc s open c Check all connections in brine line for leaks d See Table 1 for suggested salt settings System using more or less salt than salt setting a Inaccurate setting a Correct salt setting Refer t...

Страница 17: ...storage tank into the resin tank Calendar Override Regeneration If a normal demand based regeneration does not occur the Model 960 Control regenerates the system after a preset number of days Your de...

Страница 18: ...Copyright 2000 1999 Osmonics Printed in the USA P N 1017934 Rev C...