background image

We recommend to independently conduct the following services: 

 

For optimum performance, the heater should be taken to a specialized service center 
for inspection and maintenance at least once a year. 

 

If the heater is not in use, it is necessary to operate it once a month for 5-10 minutes, 
including the warm season, to ensure reliable operation of the heater . 

 

Regularly check the battery charge. 

 

Before the start of the heating season, check the fuel tank. If the tank stored fuel for a 
long time (for example from the past heating season), it is necessary to drain it! Rinse 
the tank with gasoline or kerosene and fill it with fresh diesel fuel. This procedure is 
designed to remove sediment formed in the fuel during prolonged storage. Failure to 
follow this procedure can lead to clogging or failure of the fuel pump and increased 
sooting in the combustion chamber. 

 

In case of a long parking or storing the vehicle, disconnect the heater from the power 
source (battery) to prevent it from discharging (current consumption of the heater out 
of service is (30 ÷ 40) mA). 

 

Reliable  operation  of  the  heater  depends  on  the  grade  of  fuel  used.  F uel  grade  is 
selected depending on ambient temperature.

 

 

  Malfunctions

 

.

 

Actions in the event of a malfunction. 

 

check for the presence of fuel in the tank and the fuel line downstream of the fuel 
pump; 

 

check the 25A fuses; 

 

check  for  loose  connections  in  connectors  and  fuse  holders  (possible  oxidation  of 
contacts); 

 

disconnect the power connector for 1-2 minutes and re-connect it again. 

All  other  problems  can  be  identified  by  the  fault  code,  which  is  displayed  on  the 
Controller. 

 

Attention! 

If,  during  start-up  and  operation  of  the  heater  the  error  message 

"Overheating" is repeated 3 times in a row, the heater will be locked. Locking is made 
upon actual overheating, regardless of input from the sensors that produced errors. In case 
of locking, the controller display will show code 33. To unlock the heater you need to 
contact a service center. 

 

We recommend not to wait for the lock of the heater, and immediately after the first 

overheating start troubleshooting causes of failure. 

Check intake and output of the heating unit for free passage of heated air.  

 

 

 

Содержание PLANAR-2D

Страница 1: ...Operation manual Air heater PLANAR 2D PLANAR 4DM2 12 24 PLANAR 44D 12 24 GP PLANAR 8DM 12 24 EN...

Страница 2: ...ater must be carried out only by specialists in accordance with the installation instructions Health hazard The heater may only be used for the purposes specified in this manual Due to the risk of poi...

Страница 3: ...tdown of the heater Setting of operation time Power Control Temperature Control Setting of ventilation mode Temperature indication Indication of a selected temperature sensor Remote Control Starting t...

Страница 4: ...rformed up to three times 3 in case of overheating of the heater coil for example due to blocked intake or output of the heating unit the heater is automatically switched off 4 if the maximum temperat...

Страница 5: ...scharging current consumption of the heater out of service is 30 40 mA Reliable operation of the heater depends on the grade of fuel used Fuel grade is selected depending on ambient temperature Malfun...

Страница 6: ...ax min 0 76 0 42 0 9 0 42 Power consumption W max min max min 75 8 90 9 Start up and Shutdown manual Mass kg max 12 Characteristics Models PLANAR 44D 12 GP P PLANAR 44D 24 GP P Rated voltage V 12 24 F...

Страница 7: ...min 0 24 0 1 0 24 0 1 Power consumption W max min max min 29 10 29 10 Start up and Shutdown manual Mass kg max 10 Characteristics Models PLANAR 4DM2 12 P PLANAR 4DM2 12 P Rated voltage V 12 24 Fuel di...