Responsibility

 

.

 

 

Failure  to  follow  these  instructions  and  the  requirements 

contained therein results in the exclusion of any liability on the part 
of  the  manufacturer. The same  applies to the repair specialist who 
does not have the necessary qualifications, or uses non-original parts 
without obtaining a permission of the manufacturer.

 

If you have any problems, we strongly recommend that you contact authorized service 

centers, addresses and telephone numbers of which you can find out from the company, the 
seller or on the website www.autoterm.ru. 

Automatic Control Features

 

.

 

1) 

if for some reason the heater did not start, the start-up process will be automatically 
repeated. After two failed attempts the heater will be switched off; 

2) 

if during the heater's operation burning is interrupted, the heater automatically re-starts. 
Restarts after consecutive flameouts are performed up to three times; 

3) 

in case of overheating of the heater coil (for example, due to blocked intake or output 
of the heating unit), the heater is automatically switched off; 

4) 

if the maximum temperature of the heated air is exceeded  (for example, due to closed 
outlet of the heating unit), the heater is automatically switched off; 

5) 

if voltage drops below 20V (10V) or increases to  more than 30V  (16V), the heater 
automatically  switches  off.  The  numbers  in parentheses  are  for  the heaters  with  the 
nominal voltage of 12V; 

6) 

in  case  of  emergency  shutdown,  the  appropriate  fault  code  is  displayed  on  the 
Controller display and a LED starts flashing; 

7) 

*if any of the temperature sensors is faulty, the heater does not start and displays a fault 
code 32 or 11; 

 

* - only for the heaters of the PLANAR-8D type.

 

 

  Maintenance

 

.

 

It is recommended to send the heater for regular maintenance and testing to specialized 

service centers. 

Many types of repairs and maintenance works on the heater 

require  professional  knowledge  and  special  tools.  Improper 
maintenance can result in damage to the heater. 

 

 

 

Содержание PLANAR-2D

Страница 1: ...Operation manual Air heater PLANAR 2D PLANAR 4DM2 12 24 PLANAR 44D 12 24 GP PLANAR 8DM 12 24 EN...

Страница 2: ...ater must be carried out only by specialists in accordance with the installation instructions Health hazard The heater may only be used for the purposes specified in this manual Due to the risk of poi...

Страница 3: ...tdown of the heater Setting of operation time Power Control Temperature Control Setting of ventilation mode Temperature indication Indication of a selected temperature sensor Remote Control Starting t...

Страница 4: ...rformed up to three times 3 in case of overheating of the heater coil for example due to blocked intake or output of the heating unit the heater is automatically switched off 4 if the maximum temperat...

Страница 5: ...scharging current consumption of the heater out of service is 30 40 mA Reliable operation of the heater depends on the grade of fuel used Fuel grade is selected depending on ambient temperature Malfun...

Страница 6: ...ax min 0 76 0 42 0 9 0 42 Power consumption W max min max min 75 8 90 9 Start up and Shutdown manual Mass kg max 12 Characteristics Models PLANAR 44D 12 GP P PLANAR 44D 24 GP P Rated voltage V 12 24 F...

Страница 7: ...min 0 24 0 1 0 24 0 1 Power consumption W max min max min 29 10 29 10 Start up and Shutdown manual Mass kg max 10 Characteristics Models PLANAR 4DM2 12 P PLANAR 4DM2 12 P Rated voltage V 12 24 Fuel di...

Отзывы: