35
Annex 5: Periodic maintenance table
Service object, description of activities and
maintenance technique
Required
inspection
Required
materials,
tools
Type of maintenance
PERIODIC
SEASONAL
Electrical equipment
Check the security of the attachment
of the heater electrical contacts. In case of
dirt or oil deposit on the contacts, remove
with suede moistened in petrol. In case of
carbon deposit on the operating interface of
contacts, smooth it out with fine glass
paper № 150 and wipe with petrol.
Visual
inspection
petrol,
white spirit
Every 500h
+
Air intake
Dismantle the air intake, rinse with
petrol and clean out the net by blowing
with compressed air
Visual
inspection
Petrol
(acetone)
Every 500h
+
Glow plug (for FLOW 14D)
-
Dismantle the air intake, remove
rubber cap protecting the glow plug,
disconnect the leads, unscrew the ignition
plug and remove carbon deposit from it.
-
Check the glow plug rubber cap for
mechanical damage. If this is the case,
replace the glow plug.
Visual
inspection
S=17
wrench,
clean rags,
benzene
(acetone),
screwdriver
Every 500h
+
Combustion chamber
Clean up the
1.5 mm hole for air supply
to the ignition plug
Visual
inspection
S=17
wrench,
screwdriver
Every 500h
+
Fuel pump
Prevention of formation of viscous film
deposits on driving parts of the fuel pump.
Start heater
-
Monthly
+
Fluid system
Clean up the heat exchanger
Visual
inspection
screwdriver,
brush, tank
for cooling
liquid
Every 500h
-
Fuel system
Check the fuel pipe for leakage; tighten up
clamp connections, if necessary.
Visual
inspection
screwdriver
Every 500h
+