Annex 1: Basic parameters & specifications of heaters
1.
Basic parameters of the heater FLOW-5D, 5B
Characteristics
Models
FLOW 5B
FLOW 5D
Voltage
12V
12V
24V
Heating medium
Coolant, antifreeze coolant
Optimal liquid/coolant
volume
10 - 12 L
Coolant liquid flow rate
At 0 bar pressure:
At 0.18 bar pressure:
1200 l/h
800 l/h
Heating power
5 kW
Power consumption
42 W
Power consumption, at start
122 W
120 W
Max. work altitude (MASL)
1000 m
Fuel
Petrol fuel in accordance
with EN228
Diesel fuel in accordance with
EN590
Fuel consumption
0,7 l/h max
0,62 l/h max
Control mode
Manual, standard remote control, modem
Weight of the heater
2,4 kg
Heater dimensions
220x90x136 mm
2.
Basic parameters of the heater FLOW-14D
Characteristics
Models
FLOW 14D-12
FLOW 14D-24
Voltage
12V
24V
Heating medium
Coolant, antifreeze coolant
Optimal liquid/coolant
volume
25 - 30 L
Coolant liquid flow rate
At 0 bar pressure:
At 0.18 bar pressure:
2000 l/h
1300 l/h
Heating power
14,5 kW
Power consumption
46-124 W
46-113 W
Max. work altitude (MASL)
1000 m
Fuel
Diesel fuel in accordance with EN590
Fuel consumption
0,5-1,2 l/h max
Control mode
Manual, standard remote control, modem
Weight of the heater
5,7 kg
Heater dimensions
340x160x206 mm