PROBLEM 

POSSIBLE CAUSE AND SOLUTION 

Lift Raises, Then Lowers 
Slowly. 

Down solenoid may not be seating. Remove solenoid coil and 
check. If lift does not hold with solenoid coil removed, remove 
and clean down valve cartridge or replaced as necessary

 
Oil line, hose, or fitting may be leaking. Check and repair if 
necessary. 

 
Check valve in pump assembly may not be seating. This is 
indicated by pump shaft and motor turning backward on their 
own with no power applied. Generally, this condition can be 
heard. Replace pump assembly. 

Lift Lowers Slowly. 
 

Down solenoid is not operating properly due to debris or 
damage. 

 
Check for pinched tubing or hose. Where pipe is used, check for 
obstruction in line. 
 
Thick oil due to low ambient temperatures. Add or replace with 
lower weight oil that stays thin in cold conditions (5W-15, etc.) 

 

If foam is visible in tank oil, check for loose connection in 
suction line between pump and tank. Tighten connections. 

Lift Does Not Raise.  

Motor rotation for a 3-phase motor may be reversed. Reverse 
two motor electrical leads. 
 
Check for line or hose leak. 
 
Check for low oil in reservoir. Add specified oil as necessary. 
 
Load may exceed rating. See the Specifications section. 
Remove excess load. 
 
Suction screen may be clogged, starving pump. Remove and 
clean screen. Drain and replace oil. 
 
Suction line may be leaking air due to a loose fitting. Tighten as 
needed. 

Содержание American Lifts P-25-005

Страница 1: ...1 MANUAL DE INSTALACI N OPERACI N Y SERVICIO ELEVADOR COMPACTO 1058 West Industrial Avenue Guthrie OK 73044 1058 888 811 9876 405 282 5200 FAX 405 282 3302 www autoquip com Art culo 830AMP Versi n 4 0...

Страница 2: ...3 Operation 9 3 4 Hydraulics 9 3 5 Maintenance 11 3 6 Modifications Error Bookmark not defined 3 7 Labels 12 4 Installation 15 4 1 Pit Installation 15 4 2 Shimming And Anchoring Lift To Concrete 18 4...

Страница 3: ...arse en el recibo de entrega Adem s de esta inspecci n preliminar inspeccione cuidadosamente el elevador para ver si hay da os ocultos Los da os ocultos encontrados que no se hayan registrado en el re...

Страница 4: ...torizado que haga funcionar el elevador 1 2 6 Antes de la operaci nefore Operation Antes de usar el elevador el operador debe hacer lo siguiente Leer o haber explicado y entendido las instrucciones de...

Страница 5: ...erza mayor accidentes o que se hayan usado de una manera contraria a las limitaciones o recomendaciones del fabricante seg n se indica en el manual o que se hayan reparado alterado o modificado de cua...

Страница 6: ...dad de levanta miento lb Despla zamient o pulg Altura bajada pulg Altura subida pulg Carga m xima del extremo lb Carga lateral m xima lb Plataforma est ndar m nima pulg Tiempo de subida seg No de cili...

Страница 7: ...a no pueden reemplazarse La bomba puede operar de forma eficiente a presiones intermitentes de hasta 2000 psi y servicio continuo a 1500 psi La v lvula de alivio de seguridad instalada en f brica en l...

Страница 8: ...dica una situaci n peligrosa que de no evitarse producir la muerte o lesiones graves PRECAUCI N Indica una situaci n peligrosa que de no evitarse producir lesiones menores o moderadas AVISO Indica una...

Страница 9: ...la muerte Los elevadores que se desplazan a una elevaci n por encima del nivel del piso donde la distancia entre el piso y el lado inferior de la plataforma de elevaci n sea mayor que 60 debe tener el...

Страница 10: ...nexi n giratoria entre el HVF y el cilindro Si el HVF est instalado indebidamente no se trabar en caso de falla de una tuber a hidr ulica Los fluidos a presi n pueden penetrar en la piel Las mangueras...

Страница 11: ...nunca debajo del elevador hasta que se retire la carga y el mecanismo de las tijeras est fijamente bloqueado en la posici n subida con los dispositivos de mantenimiento 3 6 Modificaciones Impida lesi...

Страница 12: ...3 7 Etiquetas To protect against death or serious injury all labels must be on lift and must be legible If any of these labels are missing or cannot be read call Autoquip for replacement labels i WARN...

Страница 13: ...13 1 36401487 2 36430050 3 36401560 4 36403230...

Страница 14: ...14 5 DECAL_CAPACITY 6 36403343 7 36400257 9 36433670...

Страница 15: ...h Federal Regulations Guarding must be installed prior to operating lift 1 Check pit dimensions Pit must be 2 longer and 2 wider than lift platform to allow a 1 gap between platform and pit Pit depth...

Страница 16: ...D If needed shim to desired height DO NOT spot shim Shim along full length of frame This will prevent frame from sagging under load Prevent serious injury or death Electrical service installation mus...

Страница 17: ...nue to hold down control for 60 seconds Repeat procedure five to seven times to bleed air out of hydraulic system 9 Raise and lower lift as needed to make positioning adjustments 10 Adjust platform to...

Страница 18: ...nvironmentally safe manner 15 Touch up paint is available from Autoquip for repair of damaged paint surfaces 16 Train personnel on lift operation all safety features and procedures 4 2 Shimming And An...

Страница 19: ...30 460 Volt 60 hertz 3 phase Super Torque intermittent duty motor with one full lift cycle per 2 minute period driving a high pressure positive displacement pump assembly with an internal relief valve...

Страница 20: ...of lift may result in excessive wear and damage to lift Prevent serious injury or death Personnel must maintain a safe operating distance of at least 36 any time lift is operated 1 Verify all personn...

Страница 21: ...vices are designed to support an unloaded lift only Failure to remove the load from the lift prior to blocking could cause the failure of the maintenance devices and allow the lift to fall unexpectedl...

Страница 22: ...SHA electrical lock out tag out procedures Disconnect and tag all electrical and or other power sources to prevent an unplanned or unexpected actuation of the lift 7 Once inspection or work is complet...

Страница 23: ...placing faulty component Check that oil pressure does not exceed 2 000 psi Check all pivot joints roller bearings for noise and wear Check overall condition of unit i e bends breaks loose or missing s...

Страница 24: ...ation Environment Ambient Temperature Recommended Oil Indoor locations with variable temperatures 30 100 degrees F 5W 30 or 5W 40 Multiviscosity Motor Oil Indoor locations with constant temperatures 6...

Страница 25: ...electrical power to lift Follow lock out tag out procedure 3 Disconnect hose on cylinder base end and insert into oil fill hole of reservoir 4 Remove pin A on cylinder rod 5 Remove bolts and retaining...

Страница 26: ...on the base of the cylinder when ordering parts 6 3 1 3 Assemble Cylinder Style A 1 Position piston on threaded rod Verify static O ring is in place between piston and rod 2 Install self locking nut...

Страница 27: ...27 6 3 1 4 Disassemble Assemble Cylinder Style B 6 3 1 5 Disassemble Assemble Cylinder Style C...

Страница 28: ...stem to malfunction Prevent serious injury or death HVF is attached to elbow fitting in rod port of cylinder Do not use a swivel fitting between HVF and cylinder If HVF is installed improperly it will...

Страница 29: ...y or death Never go under lift platform until load is removed and scissors mechanism is securely blocked in raised position with maintenance devices and hydraulic pressure is relieved The HVF is attac...

Страница 30: ...ock securely See Maintenance Devices 2 Install one end of new hose to cylinder fitting 3 Since hose is fixed at both ends it is possible to put a twist in hose that will allow it to describe the same...

Страница 31: ...31 Generic Hydraulic Schematic 1 HP...

Страница 32: ...32 Generic Hydraulic Schematic 1 5HP contractor...

Страница 33: ...33 Generic Hydraulic Schematic 5HP Heavy Duty Power Unit...

Страница 34: ...34 General Electrical Schematic 1 2HP 115V...

Страница 35: ...35 General Electrical Schematic 1 2HP 115V...

Страница 36: ...36 General Electrical Schematic 1 1 1 2HP 115V...

Страница 37: ...37 General Electrical Schematic 1 1 1 2HP 115V...

Страница 38: ...38 Generic Electrical Schematic Controls...

Страница 39: ...39 Generic Electrical Schematic Controls...

Страница 40: ...ag out procedure See Maintenance Devices section Pressurized fluids can penetrate the skin Hydraulic hoses can fail from age damage and exposure Do not search for hydraulic leaks without body and face...

Страница 41: ...due to debris or damage Check for pinched tubing or hose Where pipe is used check for obstruction in line Thick oil due to low ambient temperatures Add or replace with lower weight oil that stays thin...

Страница 42: ...ired burned out not rated for the voltage or line voltage may be excessively low Check voltage near coil Velocity fuse may be locked Do not attempt to remove the velocity fuse The following steps shou...

Страница 43: ...hile pump is idling Inadequate wiring can starve motor even when source voltage is ample Most of Autoquip s standard motors are rated for intermittent duty If a single phase motor is being run more th...

Страница 44: ...44 8 PARTS LISTS Standard Power Unit Contractor Style Power Unit...

Страница 45: ...45 Heavy Duty Power Unit...

Страница 46: ...46 Lift Parts Diagram...

Отзывы: