–The module turns off the heater if battery voltage lowers to the adjusted limit

Troubleshooting

If a run-time error occurs during the heater operation, Autoplugin Key informs
about error code with LED flashing. The number of flashes in series corresponds to 
the error code. See table 2 for errors description and possible solutions.

Table 2

Error 
Code

Error 

Description

Possible Reasons of 

Error Appearance

Solutions

2

No answer 
from the 
heater 
followed the 
start 
command

Outer temperature 
displayed in the CIP is 
higher than +14 Celsius 
degrees

The heater operates only at
temperatures below +15°C. It 
is heater manufacturer
restriction

Fuel level in the fuel 
tank is close to empty 
(“Fuel Low” warning 
indicator is illuminated
in the CIP)

Refuel the car

The heater was blocked 
after 3 unsuccessful 
starts

Try to start the heater from
CIP’s menu. If it doesn’t start
up, make diagnostics of the 
heater.

3

Battery low

The module has 
determined that battery 
voltage is below one 
specified by settings 
(items 3.1 and 3.2)

Charge the battery with special 
charger (or start the engine to 
charge) or cancel 3.1/3.2 
module’s settings

4

Time limits 
exceeded 

Time limit for 
autonomous operation of 
the heater is achieved

Run the engine or cancel 1.1 
module’s settings

5

Unsuccessful 
start

The heater was switched 
off spontaneously at 
startup

Make diagnostics of the heater 
if the error appears again

Содержание Key-V2

Страница 1: ...Autoplugin Key V2 Version 9 8 User Manual Rev D...

Страница 2: ...age Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined Instrument Panel PCC...

Страница 3: ...autonomous operation Package Content 1 Autoplugin Key V2 cartridge 2 User Manual brochure Connection The module needs that 2 timers and direct start stop function for the heater control are present i...

Страница 4: ...and the brakes pedal are used to enter Setup mode and to change the settings It is necessary to stop the engine and the heater before Turn the ignition on by holding the engine start button for at lea...

Страница 5: ...instrument panel use LED s indication of the module for settings change Settings table 1 Settings Group Settings Item Possible Values 1 Heater operation time 1 1 Limitation of total operational time o...

Страница 6: ...ep operating the heater in pre heat mode 1 3 2 1 Not adjusted 3 2 2 11 4V 3 2 3 11 5V 3 2 4 11 6V 3 2 5 11 7V 3 2 6 11 8V 3 2 7 11 9V 3 2 8 12 0V 6 Indication with direction indicators in rearview mir...

Страница 7: ...Celsius degrees The heater operates only at temperatures below 15 C It is heater manufacturer restriction Fuel level in the fuel tank is close to empty Fuel Low warning indicator is illuminated in the...

Страница 8: ...from OBD II socket and reconnect it 9 Settings error Settings have been stored incorrectly Reset the settings with 8 1 1 code readjust the module 11 Heater no connection The heater is unplugged or out...

Отзывы: