7
8.
Service
menu
8.1.
Default Settings
8.1.1
Apply factory settings
* Factory setting
Recommended settings marked in Italics
1
–The module turns off the heater if battery voltage lowers to the adjusted limit
Troubleshooting
If a run-time error occurs during the heater operation, Autoplugin Key informs
about error code with LED flashing. The number of flashes in series corresponds to
the error code. See table 2 for errors description and possible solutions.
Table 2
Error
Code
Error
Description
Possible Reasons of
Error Appearance
Solutions
2
No answer
from the
heater
followed the
start
command
Outer temperature
displayed in the CIP is
higher than +14 Celsius
degrees
The heater operates only at
temperatures below +15°C. It
is heater manufacturer
restriction
Fuel level in the fuel
tank is close to empty
(“Fuel Low” warning
indicator is illuminated
in the CIP)
Refuel the car
The heater was blocked
after 3 unsuccessful
starts
Try to start the heater from
CIP’s menu. If it doesn’t start
up, make diagnostics of the
heater.
3
Battery low
The module has
determined that battery
voltage is below one
specified by settings
(items 3.1 and 3.2)
Charge the battery with special
charger (or start the engine to
charge) or cancel 3.1/3.2
module’s settings
4
Time limits
exceeded
Time limit for
autonomous operation of
the heater is achieved
Run the engine or cancel 1.1
module’s settings
5
Unsuccessful
start
The heater was switched
off spontaneously at
startup
Make diagnostics of the heater
if the error appears again