background image

5

If the entered digit is not correct, press and release “Read/OK” button until the 
module indicates an error. Enter the code once more in that case. Several codes can 
be entered without exit of setup mode. 
Turn the ignition off to exit from the Setup mode. New settings are saved in the 
non-volatile memory of the module and stored there regardless of whether the 
module is connected or not. 

Note:

start the engine inside the Setup mode if you 

want to exit without saving of new settings.
To reset the module to the factory settings, enter the code 8.1.1. Both direction 
indicators in the CIP should flash three times, confirming command execution. 
Then the module exits Setup mode and restarts. 

* Direction indicators flash in Setup mode only in cars with analogue instrument 
panel. For cars with digital instrument panel use LED’s indication of the module
for settings change.

Settings table (1)

Settings 
Group

Settings 
Item

Possible Values

1.

Heater 
operation 
time

1.1. 

Limitation of 

total operational 
time of the heater in 
pre-heat mode

1.1.1

*Not adjusted

1.1.2

40 minutes

1.1.3

50 minutes

1.1.4

60 minutes

1.1.5

70 minutes

1.1.6

80 minutes

1.1.7

90 minutes

1.1.8

100 minutes

1.1.9

120 minutes

1.2.

Limitation of 

one-cycle 
operational time of 
the heater in pre-
heat mode 

1.2.1  

10 minutes

1.2.2  

15 minutes

1.2.3  

20 minutes

1.2.4  

25 minutes

1.2.5  

30 minutes

1.2.6  

40 minutes

1.2.7  

50 minutes

1.2.8  *

Not adjusted

2.

Heater 
control with
remote 
control key

2.1. 

“Lock” and 

“Lamp” buttons’
functions for heater 
control

2.1.1

*”Lock” button for the heater start, 

“Lamp” button for the heater stop  

2.1.2

“Lamp” button for the heater start, 

“Lock” button for the heater stop

2.2.

Number of 

sequential “Lamp” 
button presses for 
heater control

2.2.1  

Combination is disabled 

2.2.2  *

Four presses

2.2.3  

Six presses

2.2.4  

Eight presses

Содержание Key-V2

Страница 1: ...Autoplugin Key V2 Version 9 8 User Manual Rev D...

Страница 2: ...age Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined Instrument Panel PCC...

Страница 3: ...autonomous operation Package Content 1 Autoplugin Key V2 cartridge 2 User Manual brochure Connection The module needs that 2 timers and direct start stop function for the heater control are present i...

Страница 4: ...and the brakes pedal are used to enter Setup mode and to change the settings It is necessary to stop the engine and the heater before Turn the ignition on by holding the engine start button for at lea...

Страница 5: ...instrument panel use LED s indication of the module for settings change Settings table 1 Settings Group Settings Item Possible Values 1 Heater operation time 1 1 Limitation of total operational time o...

Страница 6: ...ep operating the heater in pre heat mode 1 3 2 1 Not adjusted 3 2 2 11 4V 3 2 3 11 5V 3 2 4 11 6V 3 2 5 11 7V 3 2 6 11 8V 3 2 7 11 9V 3 2 8 12 0V 6 Indication with direction indicators in rearview mir...

Страница 7: ...Celsius degrees The heater operates only at temperatures below 15 C It is heater manufacturer restriction Fuel level in the fuel tank is close to empty Fuel Low warning indicator is illuminated in the...

Страница 8: ...from OBD II socket and reconnect it 9 Settings error Settings have been stored incorrectly Reset the settings with 8 1 1 code readjust the module 11 Heater no connection The heater is unplugged or out...