OPERATING INSTRUCTIONS

CO

2

 PPM SETTINGS

CO

2

 LEVELS: Click the CO2 PPM knob and turn to set the PPM target. Click again to confirm the 

setting.   
CO

2

 DEADBAND: Click the DEADBAND knob and turn to set the desired deadband setting. Click 

again to confirm the setting.   

Example:

 For CO

2

 increase mode, if setpoint=1000 PPM and deadband=50 PPM, the CO

2

 output will 

start to work at or below 1000 and turn off at 1050 PPM. For CO

2

 decrease mode, the fan will start at 

or above 1000 PPM and turn off at 950 PPM.

MIN/MAX RECALL: Click and hold the CO

2

 PPM and DEADBAND knobs simultaneously to display 

the CO

2

 min/max PPM record. The display will show L XXX, H XXX. The screen will return to normal 

display after 5 seconds (or immediately if you click both knobs simultaneously again), and the 

record will be reset.
CALIBRATION: Place the CO

2

 sensor outdoors, press both knobs for 3 seconds, display screen reads 

CAL/400, if you need to change the calibration level, turn the left knob. Keep the sensor from direct 

sunlight and any breathing. Allow it 10 minutes to stabilize the PPM reading. The Screen will return 

to normal display once the calibration is complete.

CO

2

 & TEMP LOCK/UNLOCK SWITCH

LOCK: This setting will not allow the CO

2

 and Temp outlets to run simultaneously. The CO

2

 outlet 

will always be deactivated when the Cooling outlet is activated On. Lock setting is recommended 

for rooms applying CO

2

 that are also operating an exhaust fan for temperature control. This setting 

minimizes CO

2

 loss when the exhaust fan is operating. 

UNLOCK: The CO

2

 enrichment device and any cooling device that is plugged in are independently 

controlled.

TEMPERATURE SETTINGS

The unit offers both day and night temperature control. Select either the heating or cooling mode 

option.
DAY TEMP SETTING: There is a Day Cooling set point and a Day Heating set point.
1.  To set the Day Cooling, Click the DAY TEMP knob. “COOL” will be displayed. To change the 

setting, turn the DAY TEMP knob to select your desired temperature. Click again to accept the 

new setting.

2.  “HEAT” will then be displayed. Turn the DAY TEMP knob to select your desired setting, then click 

the knob again to save the new setting.

NIGHT TEMP SETTING: Night temps are set exactly the same way as described above for day 

temps, but using the NIGHT TEMP knob this time.
TEMP MIN/MAX RECALL: Press the DAY TEMP and NIGHT TEMP knobs simultaneously to recall the 

min/max temperature record.
TEMP UNIT: Press and hold the DAY TEMP and NIGHT TEMP knobs simultaneously knobs for 3 

seconds, then turn the DAY TEMP knob to select the desired temperature unit (°F or °C). Press both 

simultaneously again to confirm the setting.

HUMIDITY & TEMPERATURE (RH% & TEMP) LOCK/UNLOCK SWITCH

LOCK: This setting locks both the temperature and humidity outlets together making them operate 

simultaneously. Example: if the sensor detects a reading outside of the programmed Temperature 

setting the unit will activate both Temperature and Humidity outlets at the same time. Use this 

7

Содержание ECLIPSE F90

Страница 1: ...APE4200 USER MANUAL ECLIPSE F90 Master Environmental Controller AutopilotControllers com ...

Страница 2: ...AutopilotControllers com 2 ...

Страница 3: ...UMIDITY SETTINGS 8 HUMIDITY DEADBAND HYSTERESIS 8 HUMIDITY MIN MAX RECALL 8 HUMIDITY MODE SWITCH 8 TEMP DEADBAND OPTIONS 8 TEMP DEADBAND SETTING 8 CO2 MODE 8 HIGH TEMPERATURE PROTECTION 8 HOW TO SET HIGH TEMP LIMIT 8 DAYTIME MODE LED ERROR LEDS ERROR DISPLAY MESSAGES 9 SPECIFICATIONS 9 MOUNTING INSTRUCTIONS 10 MOUNTING THE UNIT TO A WALL 10 MOUNTING THE UNIT TO A GROW TENT 10 GENERAL WARNINGS 11 S...

Страница 4: ...tive covers that prevent atmospheric moisture from entering the device through any unused outlets Rubber feet have also been added to the back of the unit for added protection when mounted This controller s sensitive and intelligent remote combination probe features a highly accurate dual beam NDIR CO2 sensor The probe can be placed up to 15 feet from the controller and has been designed to resist...

Страница 5: ...PARTS LIST WHAT S IN THE BOX A B A Controller Unit B Sensor Unit C Mounting Hardware for walls D Mounting Hardware for grow tents D C 5 ...

Страница 6: ...Y SETTING HUMIDITY MODE CO2 MODE HEATING OUTPUT COOLING OUTPUT CO2 OUTPUT HUMIDITY OUTPUT TEMP DEADBAND TEMP SETTING Click press knob turn to set click again to confirm Press both function knobs for Min Max recall Press both knobs for 3 seconds to calibrate CO2 Sensor Switch F C PHOTOCELL STATUS POWERINPUT SENSORCORD 6 ...

Страница 7: ...ying CO2 that are also operating an exhaust fan for temperature control This setting minimizes CO2 loss when the exhaust fan is operating UNLOCK The CO2 enrichment device and any cooling device that is plugged in are independently controlled TEMPERATURE SETTINGS The unit offers both day and night temperature control Select either the heating or cooling mode option DAYTEMP SETTING There is a Day Co...

Страница 8: ...arget and deadband hysteresis Click again to confirm the setting CO2 MODE PPM UP Increases the CO2 PPM when using a gas CO2 generator Fuzzy Logic Increases the CO2 PPM when using a compressed CO2 system PPM DOWN Decreases the CO2 PPM using a fan HIGH TEMPERATURE PROTECTION If when using a CO2 generator with this controller the environmental temperature exceeds the set limit the ECLIPSE F90 will de...

Страница 9: ...D Press either of the corresponding knobs either of theTEMP or RH knobs to reset the error There are also four error LEDs on the bottom left of the controller These lights will identify which environmental factor the controller is reporting an error on SPECIFICATIONS Max amperage 14 5 amps 120VAC 60 Hz Power cord length 6 5 2 m Sensor cord length 15 4 5 m CO2 Range 400 2000 PPM CO2 Accuracy 100 PP...

Страница 10: ... Secure the controller to one of the grow tent s vertical support rods with the included U bolt brackets 1 Install on the inside of the grow tent 2 Install on the outside of the grow tent note that this method requires puncturing four holes through the grow tent wall to allow the threaded ends of the U bolts to emerge through the grow tent s fabric wall 1 2 10 ...

Страница 11: ...the power cord is damaged please stop using the product immediately Unplug the unit and contact the retailer you purchased it from 10 The unit is equipped with a circuit breaker that will automatically shut it down at once All outlets of the product all have the safety ground 11 Do not install the unit near any heat source 12 Do not block any ventilation openings in the controller housing 13 This ...

Страница 12: ...on of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APE4200 covered under this warranty if it is returned to the original place of purchase To request warranty service please return the APE4200 with original sales receipt and original packaging to your place of purchase The purchase date is bas...

Отзывы: