Thank you for purchasing the Autopilot ECLIPSE F90

 (APE4200)

 Master Environmental Controller. 

The ECLIPSE F90 offers integrated digital command of critical grow room conditions. Autopilot takes 

full atmospheric control and lets you get back to growing. The F90 precisely controls temperature, 

humidity, and CO

2

 PPM levels in the growing area. Its three large LED displays make monitoring 

and adjusting these environmental conditions a breeze. Three screens continuously display current 

temperature, humidity and CO

2

 PPM levels, and its LED lights indicate active modes and inform the 

user of any errors. The ECLIPSE F90 Master Environmental Controller is easy to program and operate 

while showcasing total transparency of environmental conditions 24 hours a day.
The ECLIPSE F90’s enclosure features four separate power outlets for external control of cooling (AC 

or exhaust fan), heating, CO

2

 (regulator or generator), and humidity (humidifier or dehumidifier). 

These outlets feature heavy duty protective covers that prevent atmospheric moisture from 

entering the device through any unused outlets. Rubber feet have also been added to the back of 

the unit for added protection when mounted. 
This controller’s sensitive and intelligent remote combination probe features a highly accurate dual 

beam NDIR CO

2

 sensor. The probe can be placed up to 15 feet from the controller, and has been 

designed to resist EMI/EFI from electronic ballasts. The controller itself comes equipped with wall 

anchors and optional U-brackets for tent mounting.
Each ECLIPSE F90 has been pre-programmed with factory recommended settings for quick plug 

and play operation. Humidity deadband, for example, is preset to 5% +/-. An adjustable Fuzzy Logic 

setting is also available for use with CO

2

 tank and regulator systems. 

For information on additional Autopilot products please visit AutopilotControllers.com.

NOTE:

 After turning on the power to the unit, it will take five minutes for the sensor to warm up.

NOTE:

 This controller has a 14.5A maximum load. For higher amperage devices such as A/C units, it is 

recommended to use a power expander.

OVERVIEW

TOOLS NEEDED - 

(FOR OPTIONAL MOUNTING)

Phillips

Screwdriver

8' (2.5 m)

minimum

4

Содержание ECLIPSE F90

Страница 1: ...APE4200 USER MANUAL ECLIPSE F90 Master Environmental Controller AutopilotControllers com ...

Страница 2: ...AutopilotControllers com 2 ...

Страница 3: ...UMIDITY SETTINGS 8 HUMIDITY DEADBAND HYSTERESIS 8 HUMIDITY MIN MAX RECALL 8 HUMIDITY MODE SWITCH 8 TEMP DEADBAND OPTIONS 8 TEMP DEADBAND SETTING 8 CO2 MODE 8 HIGH TEMPERATURE PROTECTION 8 HOW TO SET HIGH TEMP LIMIT 8 DAYTIME MODE LED ERROR LEDS ERROR DISPLAY MESSAGES 9 SPECIFICATIONS 9 MOUNTING INSTRUCTIONS 10 MOUNTING THE UNIT TO A WALL 10 MOUNTING THE UNIT TO A GROW TENT 10 GENERAL WARNINGS 11 S...

Страница 4: ...tive covers that prevent atmospheric moisture from entering the device through any unused outlets Rubber feet have also been added to the back of the unit for added protection when mounted This controller s sensitive and intelligent remote combination probe features a highly accurate dual beam NDIR CO2 sensor The probe can be placed up to 15 feet from the controller and has been designed to resist...

Страница 5: ...PARTS LIST WHAT S IN THE BOX A B A Controller Unit B Sensor Unit C Mounting Hardware for walls D Mounting Hardware for grow tents D C 5 ...

Страница 6: ...Y SETTING HUMIDITY MODE CO2 MODE HEATING OUTPUT COOLING OUTPUT CO2 OUTPUT HUMIDITY OUTPUT TEMP DEADBAND TEMP SETTING Click press knob turn to set click again to confirm Press both function knobs for Min Max recall Press both knobs for 3 seconds to calibrate CO2 Sensor Switch F C PHOTOCELL STATUS POWERINPUT SENSORCORD 6 ...

Страница 7: ...ying CO2 that are also operating an exhaust fan for temperature control This setting minimizes CO2 loss when the exhaust fan is operating UNLOCK The CO2 enrichment device and any cooling device that is plugged in are independently controlled TEMPERATURE SETTINGS The unit offers both day and night temperature control Select either the heating or cooling mode option DAYTEMP SETTING There is a Day Co...

Страница 8: ...arget and deadband hysteresis Click again to confirm the setting CO2 MODE PPM UP Increases the CO2 PPM when using a gas CO2 generator Fuzzy Logic Increases the CO2 PPM when using a compressed CO2 system PPM DOWN Decreases the CO2 PPM using a fan HIGH TEMPERATURE PROTECTION If when using a CO2 generator with this controller the environmental temperature exceeds the set limit the ECLIPSE F90 will de...

Страница 9: ...D Press either of the corresponding knobs either of theTEMP or RH knobs to reset the error There are also four error LEDs on the bottom left of the controller These lights will identify which environmental factor the controller is reporting an error on SPECIFICATIONS Max amperage 14 5 amps 120VAC 60 Hz Power cord length 6 5 2 m Sensor cord length 15 4 5 m CO2 Range 400 2000 PPM CO2 Accuracy 100 PP...

Страница 10: ... Secure the controller to one of the grow tent s vertical support rods with the included U bolt brackets 1 Install on the inside of the grow tent 2 Install on the outside of the grow tent note that this method requires puncturing four holes through the grow tent wall to allow the threaded ends of the U bolts to emerge through the grow tent s fabric wall 1 2 10 ...

Страница 11: ...the power cord is damaged please stop using the product immediately Unplug the unit and contact the retailer you purchased it from 10 The unit is equipped with a circuit breaker that will automatically shut it down at once All outlets of the product all have the safety ground 11 Do not install the unit near any heat source 12 Do not block any ventilation openings in the controller housing 13 This ...

Страница 12: ...on of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APE4200 covered under this warranty if it is returned to the original place of purchase To request warranty service please return the APE4200 with original sales receipt and original packaging to your place of purchase The purchase date is bas...

Отзывы: