GENERAL WARNINGS 

1.  Save the instructions. These safety and operating instructions must be kept in a safe place for 

future reference.

2.  All warnings on this product and in the instructions must be observed closely.
3.  All operating instructions must be followed.
4.  If the these instructions are not followed, damage to the product itself may result.
5.  Install your controller at least 8

'

 away from any devices that produce electronic interference, 

such as electronic ballasts or ozone generators.

6.  This controller can only accept standard 120V Nema 1-15P and Nema 5-15P plugs. Do not insert 

any other plug type into it.

7.  Do not use this controller near water or any water source. It should not be exposed to any 

dripping or splashing water, as it is not waterproof nor shockproof.

8.  Any serviceable parts inside or outside the unit should only be replaced by Hydrofarm.
9.  If the power cord is damaged, please stop using the product immediately. Unplug the unit and 

contact the retailer you purchased it from.

10.  The unit is equipped with a circuit breaker that will automatically shut it down at once. All 

outlets of the product all have the safety ground.

11.  Do not install the unit near any heat source.
12.  Do not block any ventilation openings in the controller housing.
13.  This product is a Safety Class I Controller and is equipped with a Nema 5-15P plug. The main 

plug should only be inserted into a properly grounded power outlet. Any alteration of the 

power cord is likely to make the product dangerous and will void the warranty.

SULFUR VAPORIZER WARNING

If a sulfur vaporizer is used, first remove the remote sensor unit from the affected area or turn 

the controller off and cover the remote sensor probe with a protective plastic bag. Remove 

the bag before turning the power back on. Failure to protect the sensor while using a sulfur 

vaporizer will result in damage to its infrared component and will void the warranty.

8' (2.5 m)

minimum

11

Содержание ECLIPSE F90

Страница 1: ...APE4200 USER MANUAL ECLIPSE F90 Master Environmental Controller AutopilotControllers com ...

Страница 2: ...AutopilotControllers com 2 ...

Страница 3: ...UMIDITY SETTINGS 8 HUMIDITY DEADBAND HYSTERESIS 8 HUMIDITY MIN MAX RECALL 8 HUMIDITY MODE SWITCH 8 TEMP DEADBAND OPTIONS 8 TEMP DEADBAND SETTING 8 CO2 MODE 8 HIGH TEMPERATURE PROTECTION 8 HOW TO SET HIGH TEMP LIMIT 8 DAYTIME MODE LED ERROR LEDS ERROR DISPLAY MESSAGES 9 SPECIFICATIONS 9 MOUNTING INSTRUCTIONS 10 MOUNTING THE UNIT TO A WALL 10 MOUNTING THE UNIT TO A GROW TENT 10 GENERAL WARNINGS 11 S...

Страница 4: ...tive covers that prevent atmospheric moisture from entering the device through any unused outlets Rubber feet have also been added to the back of the unit for added protection when mounted This controller s sensitive and intelligent remote combination probe features a highly accurate dual beam NDIR CO2 sensor The probe can be placed up to 15 feet from the controller and has been designed to resist...

Страница 5: ...PARTS LIST WHAT S IN THE BOX A B A Controller Unit B Sensor Unit C Mounting Hardware for walls D Mounting Hardware for grow tents D C 5 ...

Страница 6: ...Y SETTING HUMIDITY MODE CO2 MODE HEATING OUTPUT COOLING OUTPUT CO2 OUTPUT HUMIDITY OUTPUT TEMP DEADBAND TEMP SETTING Click press knob turn to set click again to confirm Press both function knobs for Min Max recall Press both knobs for 3 seconds to calibrate CO2 Sensor Switch F C PHOTOCELL STATUS POWERINPUT SENSORCORD 6 ...

Страница 7: ...ying CO2 that are also operating an exhaust fan for temperature control This setting minimizes CO2 loss when the exhaust fan is operating UNLOCK The CO2 enrichment device and any cooling device that is plugged in are independently controlled TEMPERATURE SETTINGS The unit offers both day and night temperature control Select either the heating or cooling mode option DAYTEMP SETTING There is a Day Co...

Страница 8: ...arget and deadband hysteresis Click again to confirm the setting CO2 MODE PPM UP Increases the CO2 PPM when using a gas CO2 generator Fuzzy Logic Increases the CO2 PPM when using a compressed CO2 system PPM DOWN Decreases the CO2 PPM using a fan HIGH TEMPERATURE PROTECTION If when using a CO2 generator with this controller the environmental temperature exceeds the set limit the ECLIPSE F90 will de...

Страница 9: ...D Press either of the corresponding knobs either of theTEMP or RH knobs to reset the error There are also four error LEDs on the bottom left of the controller These lights will identify which environmental factor the controller is reporting an error on SPECIFICATIONS Max amperage 14 5 amps 120VAC 60 Hz Power cord length 6 5 2 m Sensor cord length 15 4 5 m CO2 Range 400 2000 PPM CO2 Accuracy 100 PP...

Страница 10: ... Secure the controller to one of the grow tent s vertical support rods with the included U bolt brackets 1 Install on the inside of the grow tent 2 Install on the outside of the grow tent note that this method requires puncturing four holes through the grow tent wall to allow the threaded ends of the U bolts to emerge through the grow tent s fabric wall 1 2 10 ...

Страница 11: ...the power cord is damaged please stop using the product immediately Unplug the unit and contact the retailer you purchased it from 10 The unit is equipped with a circuit breaker that will automatically shut it down at once All outlets of the product all have the safety ground 11 Do not install the unit near any heat source 12 Do not block any ventilation openings in the controller housing 13 This ...

Страница 12: ...on of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APE4200 covered under this warranty if it is returned to the original place of purchase To request warranty service please return the APE4200 with original sales receipt and original packaging to your place of purchase The purchase date is bas...

Отзывы: