background image

-|Transparent Guide|-

Product Components

• 

Product

• 

Instruction manual

• 

Ethernet connector Cap 

 

(screw plug - waterproof) × 1 

Software

Download the installation file and the manuals from the Autonics website.

  

atVision

The program allows setting of smart camera parameters and management of 
monitoring data such as inspection status and status information.

Item

Minimum requirements

CPU

Intel i3, Ryzen 3 or above

OS

Microsoft Windows 7 (×64) or higher

RAM

6 GB or higher

Storage

 01)

at least 10 GB of available HDD space

Resolution

 02)

1280×800 or higher (1920×1080 recommended)

Others

RJ45 Ethernet port, GigE network interface card

 01)  Additional HDD space may be required depending on the number of inspections.
 02)  This software is optimized for 1920×1080 resolution and 100% magnification.

Inner Circuit

  

■ Trigger (TRIG) input

Trigger-

CIRC

UIT

VC Series

External

  

■ NPN open collector output

  

■ PNP open collector output

CIRC

UIT

LOAD

OCP

SCP

Max. 100 mA

CIRC

UIT

LOAD

OCP

SCP

Max. 100 mA

• 

OCP (over current protection), SCP (short circuit protection)

• 

If short-circuit the control output terminal or supply current over the rated specification, normal control signal is 

not output due to the output short over current protection circuit.

Connections

  

■ Power I/O connector wiring (M12 8-pin plug type connector)

• 

When the power is unstable, ground the shield of the provided cable.

Pin Color

Signal

Function

1

White

HS OUT 0 Strobe OUT

2

Brown

VCC

Power input

3

Green TRIG +

Trigger input +

4

Yellow

TRIG -

Trigger input -

5

Gray

RS232 RX RS232 receive

6

Pink

RS232 TX RS232 transmit

7

Blue

GND

Ground

8

Red

HS OUT 1 Select 1 from inspection complete, 

inspection result output (PASS / FAIL), alarm

8

7

5

6

3

1

4

2

  

■ Ethernet connector wiring (M12 8-pin socket type / RJ45 connector)

M12 8-pin

Color

RJ45

Signal

1

White / Blue

5

BI_DC-

2

White / Brown

7

BI_DD+

3

Brown

8

BI_DD-

4

Orange

2

BI_DA-

5

White / Green

3

BI_DB+

6

White / Orange

1

BI_DA+

7

Blue

4

BI_DC+

8

Green

6

BI_DB-

8

7

4

3

2

6

1

5

Network Setting

• 

Configure the network settings of vision sensor via atVision.

• 

For initial IP address, refer to the table as below.

IP address

192.168.0.2

Subnet mask

255.255.255.0

Gateway

192.168.0.1

Sold Separately

• 

Power I/O cable: CIDM8-□-A (I type), CLDM8-□-A (L type)

• 

Ethernet cable: C1(M)8-□PR-A (I type), C4(M)8-□PR-A (L type)

• 

Waterproof lens cover: HL-▭-VC

Waterproof Lens Cover Assembly

02

01

03

04

01. 

Remove the housing bushing cover by rotating CCW direction.

02. 

Remove the sensor protective cap.

03. 

Tighten the C-mount lens by rotating CW direction.

04. 

Tighten firmly the waterproof lens cover by rotating CW direction until there 
is no gap.

Unit Descriptions

01

02

04

03

05

01. 

Sensor protective cap

02. 

Housing bushing cover

03. 

Status LED indicator

04. 

Power I/O connector

05. Ethernet connector

  

Indicator

Indicator Name

Function

POWER

Power indicator (green)

Turns ON when power is supplied.

LINK

Ethernet connection indicator (green) Turns ON when vision sensor is connected 

with PC (Ethernet communication).

DATA

Data transmit indicator (green)

Flashes when data is transmitted between 

smart camera and PC.

USER 1

User setting indicator (green / red)

Turns ON or flashes in operation of 

inspection complete, inspection result 

(PASS, FAIL), alarm, camera work

USER 2

Dimensions

• 

Unit: mm, For the detailed drawings, follow the Autonics website.

72

Ø55.6

87.5

18.5

30

36

4-M4×P0.7

 

DP 6.0

62.3

Ø69.0

138.5

46.5

120

136.6

50

10.6

98

4-M4×P0.7

 

DP 7.0

106.5 / 123.5

Ø63.4

46.5

120

136.6

Содержание VC Series

Страница 1: ... Caution Failure to follow instructions may result in injury or product damage 01 Use the unit within the rated specifications Failure to follow this instruction may result in fire or product damage 02 Use a dry cloth to clean the unit and do not use water or organic solvent Failure to follow this instruction may result in fire 03 Keep the product away from metal chip dust and wire residue which f...

Страница 2: ...1 from inspection complete inspection result output PASS FAIL alarm 8 7 5 6 3 1 4 2 Ethernetconnectorwiring M128 pinsockettype RJ45connector M12 8 pin Color RJ45 Signal 1 White Blue 5 BI_DC 2 White Brown 7 BI_DD 3 Brown 8 BI_DD 4 Orange 2 BI_DA 5 White Green 3 BI_DB 6 White Orange 1 BI_DA 7 Blue 4 BI_DC 8 Green 6 BI_DB 8 7 4 3 2 6 1 5 NetworkSetting Configure the network settings of vision sensor ...

Страница 3: ... collector output setting software HS OUT 0 Strobe OUT HS OUT 1 Inspection complete Inspection result output PASS FAIL Alarm Camera work Load voltage 24 VDCᜡ Load current 100 mA Residual voltage 2 5 VDCᜡ Protection circuit Output short overcurrent protection circuit reverse voltage polarity protection circuit Vibration 1 5 mm double amplitude at frequency 10 to 55 Hz for 1 minute in each X Y Z dir...

Страница 4: ...t Read separated text from background Area Inspect the object area Angle Inspect the angle between two edges Brightness Inspect the object average brightness Contrast Inspect the object average contrast Diameter Inspect the diameter of the circle Length Inspect the distance between two edges Edge Inspect the existence of edges Object Counting Inspect the object count Shape Compare Inspect the edge...

Отзывы: