-|Transparent Guide|-
Troubleshooting
Please check routinely whether VC is operating in normal status or not. For more
information, refer to atVision software manual.
Symptom
Troubleshooting
When supplying power,
POWER LED is not
turned ON.
Check the status of power supplying and power cable are connected
properly.
Check the power is supplied within the rated range.
Check the polarity of power is connected properly.
Check the power terminal is tightened thoroughly.
Work is failed due to the
external input error.
Check whether status of input COMMON or each of input wire is
connected properly.
Check whether the problem occurs in input device work.
Work is failed due to the
external output error.
Check the output wire is connected properly.
Check the power to output is supplied within the rated range.
Check whether the problem occurs in output device work.
Check the specifications of load connected to output is within the
rated range.
Unable to
connect Ethernet
communication.
Check LINK LED is turned ON.
If not, check wiring.
Check the communication (IP address, subnet mask and gateway) is
set correctly.
Check the connection or specification of the communication cable
is corresponding to Autonics Guide. Use the cable distributed by
Autonics. (sold separately)
Model
VC-M50T-CE
Image element
1 inch mono CMOS
Resolution
5 MP (2,560 × 2,048)
Frame per second
16 fps
Bit Depth
8 bit (256 gray level)
Shutter
Global shutter
Exposure time
3 μs to 3 sec
Lens type
C-Mount
eMMC
8 GB
DDR4
2 GB (LPDDR4), 512 MB (DDR4)
Inspection work group
64 (simultaneous inspection: 32)
Trigger mode
Continuous, External Trigger, Manual, Ethernet, RS232
Communication
Ethernet (TCP/IP & Modbus, 10/100/1000Base-T), RS232C
FTP trans. output
YES
Indicator
Power, LINK, DATA, USER 1, USER 2
Approval
ᜢ ᜣ ᜨ
Unit weight
(packaged)
≈ 600 g (≈ 780 g)
Power supply
24 VDCᜡ ±10%
Current consumption
≤ 1 A
Rated input signal
24 VDCᜡ ±10%
Output signal
NPN-PNP open collector output setting (software)
HS OUT 0
Strobe OUT
HS OUT 1
Inspection complete, Inspection result output (PASS / FAIL), Alarm,
Camera work
Load voltage
24 VDCᜡ
Load current
≤ 100 mA
Residual voltage
≤ 2.5 VDCᜡ
Protection circuit
Output short overcurrent protection circuit, reverse voltage polarity
protection circuit
Vibration
1.5 mm double amplitude at frequency 10 to 55 Hz (for 1 minute) in
each X, Y, Z direction for 2 hours
Shock
300 m/s
2
(≈ 30 G) in each X, Y, Z direction for 3 times
Ambient temp.
0 to 45 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Ambient humi.
0 to 95%RH, storage: 0 to 95%RH (no freezing or condensation)
Protection structure
IP67 (IEC standard / When mounting waterproof lens cover)
Connection
Connector type
Connector spec.
Power I/O: M12 8-pin, Ethernet: M12 8-pin / RJ45 (cable tightening
torque: 0.4 N m)
Material
Die-cast Aluminum Housing
Components
Ethernet connector Cap (screw plug - waterproof) × 1
(tightening torque: 0.4 N m)
Specifications
Components: Ethernet Connector Cap
•
Ethernet connector cap protects unused Ethernet connector from
foreign substances. (tightening torque: 0.4 N m)aaaasdf
Sold Separately: Waterproof Lens Cover
•
Unit: mm, For the detailed drawings, follow the Autonics web site.
Ø47.5
Ø63.4
Ø47.5
Ø49
Ø49
Ø59.4
Ø59.4
44.2
61.3
7
A
A'
Section A-A'
[HL-57-VC]
[HL-74-VC]
Section A-A'
7
57
74
Sold Separately: Power I/O Cable
•
Unit: mm, For the detailed drawings, follow the Autonics web site.
■ CIDM8-□-A
45.4
±2
Ø 14.8
±0.5
L
±50
50
±5
M12
■ CLDM8-□-A
36.3
±1.5
28
±2
L
±50
50
±5
Ø 14.8
±0.5
M12
•
Power I/O cable is drag chain type.
•
□ of model name is 2, 5, 10 which indicates the cable length.
E.g.) CIDM8-10-A: Drag chain type 10 m power I/O cable
•
The cable tightening torque is 0.4 N m.
Sold Separately: Ethernet Cable
•
Unit: mm, For the detailed drawings, follow the Autonics web site.
■ C1(M)8-□PR-A
47.3
±1.5
L
±50
44.65
±1.5
Ø 14.8
±0.5
M12
■ C4(M)8-□PR-A
Ø 14.8
±0.5
44.65
±1.5
L
±50
36.25
±1.5
30
±2
M12
•
□ of model name is 2, 5, 10 which indicates the cable length.
(M) indicates the drag chain type cable, no mark indicates the fixed type cable.
E.g.) C1M8-10PR-A: Drag chain type 10 m Ethernet cable
•
The cable tightening torque is 0.4 N m.