289
34.2.3 Trigger tap
•
It is called when clicking add or edit button in observe status window.
•
Configure device using as trigger and trigger occurrence condition.
•
It is able to designate independent trigger condition for maximum two bit devices.
•
It executes configured function when trigger 1,2 are configured and two conditions are satisfied
simultaneously.
•
Trigger1 should be designated, but trigger2 is not required to designate necessarily.
Trigger/operation
Designation of trigger device
①
Trigger1
•
”ON”, “OFF” : Designate trigger status of trigger1.
②
Device
•
Designate trigger1 device calling device window.
③
Device
•
It is able to designate inputting directly showing designated trigger1 device.
④
Trigger2
•
”ON”, “OFF” : Designate trigger status of trigger2.
⑤
Device
•
Designate trigger2 device calling device window.
⑥
Device
•
It is able to designate inputting directly showing designated trigger2 device.
⑦
Delete
•
It makes as trigger2 is not designated.
①
②
③
④
⑦
⑤
⑥
Содержание GP Series
Страница 26: ...26 GP S057 Fixing brackets Fixing brackets LCD Screen Power terminal block ...
Страница 27: ...27 1 7 2 Dimensions Color IVORY Unit mm GP 2480 LP S044 ...
Страница 28: ...28 GP S057 1 7 3 The fixing bracket 20060407 Unit mm GP 2480 LP S044 ...
Страница 29: ...29 GP S057 ...
Страница 30: ...30 1 7 4 Panel cut out Unit mm GP 2480 LP S044 100 이상 Min 100 Over 100 Min 100 GP S057 ...
Страница 75: ...75 device and configure of word device value special function ...
Страница 122: ...122 4 Place a mouse cursor on a proper position click left button Text is arranged on a screen ...
Страница 132: ...132 Example of overlap Base screen Overlap screen Base screen after overlapping ...
Страница 234: ...234 24 3 2 Bit tap 3 6 8 9 ...
Страница 311: ...311 ...