134
11. COMMUNICATION
11.1 OUTLINE
Editor and GP main device communicate as serial through RS232C or RS422 port.
It is able to execute following operations with communication.
•
Screen data download : Download project written on editor to main device.
•
Upload main device data : Upload project stored in main device to editor.
•
Confirmation of main device memory : Confirm delete, memory for specific screen of main
device in editor.
•
Firmware download : Replace main device software as improved one.
※
Notice
In order to communicate with editor,
use a port is not used by CH1
and designate
CH2 as
“Editor”
in
[Preference]-[Channel connection]
of GP system configuration.
It is able to communicate regardless of speed, data length when connecting to editor.
11.2 DOWNLOAD DESIGN DATA
After writing screen data, select [Communication]–[Download] or
, then, screen data download
window is popped up. Pressing download button after configuration of data to be downloaded and
download option, it starts to download.
11.2.1 Precaution of configuration
(1) It is able to confirm and change communication configuration. Confirm and designate PC port
and communication speed on communication tap of operation window.
(2) When checking delete all old monitoring data, all data downloaded on main device is
deleted.
(3) When selecting all data in object group box, all data of project is downloaded and base, window,
other taps are activated, designated item is only downloaded when selecting selected data. In
window tap, it shows window screen to be downloaded, it is key window number configured in
project auxiliary configuration, it is not downloaded optionally. It is able to download selecting
comment and part among comment, part, common setting in other tap.
(4) Each project has ID and if project ID of main device and to be downloaded are different when
downloading part of project without checking delete all old data, it shows warning message for
downloading. If it is progressed, selected item is downloaded.
(5) Before downloading, execute “Data check”. If there is a problem, cancel download and adjust
data by user.
Содержание GP Series
Страница 26: ...26 GP S057 Fixing brackets Fixing brackets LCD Screen Power terminal block ...
Страница 27: ...27 1 7 2 Dimensions Color IVORY Unit mm GP 2480 LP S044 ...
Страница 28: ...28 GP S057 1 7 3 The fixing bracket 20060407 Unit mm GP 2480 LP S044 ...
Страница 29: ...29 GP S057 ...
Страница 30: ...30 1 7 4 Panel cut out Unit mm GP 2480 LP S044 100 이상 Min 100 Over 100 Min 100 GP S057 ...
Страница 75: ...75 device and configure of word device value special function ...
Страница 122: ...122 4 Place a mouse cursor on a proper position click left button Text is arranged on a screen ...
Страница 132: ...132 Example of overlap Base screen Overlap screen Base screen after overlapping ...
Страница 234: ...234 24 3 2 Bit tap 3 6 8 9 ...
Страница 311: ...311 ...