■ Time operation (for indicator model)
Count up mode
Count down mode
RESET
INHIBIT
0
+Max.
time range
RESET
INHIBIT
0
+Max.
time range
-Max.
time range
•
(-) display is only for F, K, Q, S output operation mode and it cannot be set.
S
RESET
Setting
0
Output
RESET
Setting
0
Output
Output turns OFF→ON→OFF operates repeatedly (flicker).
Mode
Output operation Description
Count up
Count down
F
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value increases or decreases until reset signal input is
applied and retained (hold) output is maintained.
N
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value and retained (hold) output are maintained until
reset signal input is applied.
C
RESET
Setting
0
Output
RESET
Setting
0
Output
When time-up, the display value is reset and it operates simultaneously.
R
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value is reset after one-shot output time and it operates
simultaneously.
K
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value increases or decreases until reset signal input is
applied.
P
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value is maintained while output is ON. The value is
internally reset and it operates simultaneously.
Q
RESET
Setting
0
Output
RESET
Setting
0
Output
After time-up, the display value increases or decreases during one-shot output time.
Output operation mode
•
Output type
One-shot output Retained (hold) output
•
Set One-shot output time via [TIME] volume switch on the front side.
Setting range: 0.05 to 5 sec