background image

1



6-DIGIT TIMER ACCUMULATES TIME IN HOURS,

1/10 HOURS, 1/100 HOURS, OR 1/10 MINUTES



OPERATES FROM EITHER SWITCH CONTACT, OR

10 to 300 V (AC 50/60 Hz or DC) INPUTS



SELF-POWERED WITH INTERNAL LITHIUM BATTERY FOR UP TO 

7 YEARS OF CONTINUOUS OPERATION



AVAILABLE IN FRONT PANEL AND REMOTE RESET OR REMOTE 

RESET ONLY MODELS



EASY SNAP-IN MOUNTING IN 1" X 2" (25 mm x 50 mm) PANEL 

OPENING



IDEAL FOR PORTABLE, MOBILE, OR STATIONARY INDUSTRIAL 

EQUIPMENT

DESCRIPTION

The CUB3T’s are state-of-the-art products with Micro-Electronic technology.  

They open up a wide variety of new timing application possibilities that, until 
now, were economically impractical.

The CUB3T3 and CUB3T4 are designed to be used as hour, tenth hour, 

hundredth hour or tenth minute timers. The timing function on both models can 
be activated by either a contact closure or the application of 10 to 300 (AC 
50/60 Hz or DC). Both models are equipped with a remote reset. The CUB3T4 
has the additional feature of a front panel reset. Time is displayed on a 6 digit 
LCD that will wrap around from a full display of “999999” to “000000” when 
an overflow occurs. An indicator, located in the upper lefthand corner of the 
display, will blink at 2 Hz whenever the timer is actuated. The front panel reset 
feature of the CUB3T4 allows the user to periodically measure elapsed time. 
The CUB3T3, on the other hand, is ideally suited for measuring total run time.

Application of the CUB3T is simplicity itself. Its rugged reinforced nylon 

case snap-fits into a standard rectangular opening without screws or other 
hardware. No external power source is required since the internal lithium 
battery provides up to 7 years of uninterrupted service. In addition to these 
advantages, the CUB3T offers integrated circuitry, embedded in a single 
monolithic, silicon micro-chip.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this 

bulletin or on equipment must be observed to ensure personal safety and to 
prevent damage to either the instrument or equipment connected to it. If 
equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired.

Metal panel must be connected to protective earth ground.

MODEL CUB3T3 & CUB3T4 - 

GENERAL PURPOSE MINIATURE ELECTRONIC TIMERS

PANEL CLASP

(ONE ON

EACH SIDE)

.150 (3.8) BEZEL

PROTRUSION FROM
PANEL FRONT

    

2.09 (53)

BEZEL

(49.3)

BODY

1.94

BODY

.95 (24.2)

1.10 (28)

BEZEL

1.72 (43.7)

BODY DEPTH

(MAX)BEHIND BEZEL

    

DIMENSIONS 

In inches (mm)

 & INSTALLATION

SPECIFICATIONS

1. 

DISPLAY:

 6-Digit, LCD, 0.2" 

(5.1 mm)

 High.

2. 

POWER:

 3 Volts supplied by a non-replaceable lithium battery. Nominal 

battery life is 7 years. Battery life is dependent upon usage. Signal and reset 
contacts that remain closed for long periods of time reduce battery life.

3. 

REMOTE RESET:

50 msec min. pulse width (active low) from 3.0 V bi-polar output, an open 

collector transistor, or a switch contact to common.

V

IH

 = 2.0 V min. (3 V max), V

IL

 = 0.5 V max.

4. 

SIGNAL INPUT:

Contact Connections

: Switch Contact or Solid-State Transistor Switch. 

Contact burden 15 

μ

A max. A maintained closed switch actuates the timer.

10 to 300 V Connections

: 10 V min. to 300 V max. (AC 50/60 Hz or DC). 

Input current 0.5 mA max. Constant voltage applied to the inputs actuates 
the timer.

5. 

CERTIFICATIONS AND COMPLIANCES:

 

SAFETY

EN 61010-1, IEC 1010-1
Safety requirements for electrical equipment for measurement, control, 

and laboratory use, Part I.

ELECTROMAGNETIC COMPATIBILITY

Notes:
1. For operation without loss of performance:

In static environments above 4 KV, typical anti-static precautions should 

be observed before touching the bezel.

2. For operation without loss of performance:

Install 1 ferrite core, RLC#FCOR0000 or equivalent, to cables at unit.

OR

Route I/O cables in metal conduit connected to earth ground.

Refer to the EMC Installation Guidelines for additional information.

6. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature

: -25 to +75°C

Storage Temperature

: -30 to 75°C

Operating and Storage Humidity

: 85% max. RH (non-condensing) from 

-25°C to +75°C.

Vibration according to IEC 68-2-6

:

 

Operational 5 to 500 Hz, in X, Y, Z 

direction for 1.5 hours, 5 g’s.

Shock according to IEC 68-2-27

: Operational 30 g, 11 msec in 3 directions

Altitude

: Up to 2000 meters

7. 

CONSTRUCTION

: Installation Category II, Pollution Degree 2.

8. 

ACCURACY:

 0.025%

9. 

WEIGHT:

 2 oz (56.7 g)

CAUTION: 

Read complete instructions prior 

to installation and operation of the unit.

CAUTION: 

Risk of electric shock.

STRAIN
RELIEF

PANEL CUT-OUT
1 x 2 or (25 x 50 )
PANEL THICKNESS
.05 to .125

Bulletin No.  CUB3T3/4-B
Drawing No.  LP0395
Revised  03/09

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Immunity to EN 50082-2

Electrostatic discharge

EN 61000-4-2 Level 2; 4 Kv contact 

1

Level 3; 8 Kv air

Electromagnetic RF fields

EN 61000-4-3 Level 3; 10 V/m 

80 MHz - 1 GHz

Fast transients (burst)

EN 61000-4-4 Level 4; 2 Kv I/O 

2

RF conducted interference

EN 61000-4-6 Level 3; 10 V/rms 

150 KHz - 80 MHz

Emissions to EN 50081-1

RF interference

EN 55022

Enclosure class B

Отзывы: