background image

A-141

Liquid Level Sensor

SENSORS

CONTROLLERS

MOTION DEVICES

SOFTWARE

(A)

Photoelectric 

Sensors

(B)

Fiber Optic

Sensors

(C)

LiDAR 

(D)

Door/Area

Sensors

(E)

Vision

Sensors

(F)

Proximity

Sensors 

(G)

Pressure

Sensors 

(H)

Rotary

Encoders 

(I)

Connectors/

Connector Cables/

Sensor Distribution 

Boxes/ Sockets

 

Operation Mode

 

Operating Timing Diagram

 

Control Output Circuit Diagram

 Connection

Load

Load

12-24VDC

-     +

Operation mode

Light ON

Receiver operation

         

Operation indicator

(red LED)

Transistor output

Operation mode

Dark ON

Receiver operation

         

Operation indicator

(red LED)

Transistor output

ON

ON

OFF

OFF

ON

ON

OFF

OFF

Absent liquid (light on)

Operation

level

ON

OFF

ON

OFF

Light ON

Present liquid (dark on)

Received light

Received light

Interrupted light

Interrupted light

Stable light ON area

Unstable operation level

Stable light OFF area

Incident

light

level

High

Low

Operation 

indicator

 (red LED)

Transistor 

output

The waveforms of 'Operation indicator' and 'Transistor output' are for Light ON, it is operated as reverse in Dark ON.

※Ifshort-circuitthecontroloutputterminalorsupplycurrentovertheratedspecification,

normalcontrolsignalisnotoutputduetotheoutputshortovercurrentprotectioncircuit.

 (brown)

+V     

 (black)

Output

 (blue)

0V

Load connection for PNP output

Load connection for NPN output

NPN

open

collector

output

Sensor circuit  

Connection

PNP

open

collector

output

Output short 

overcurrent 

protection circuit

Max. 100mA

12-24VDC

+

-

Load

12-24VDC

Main circuit

Main circuit

(brown)+V         

(brown)+V         

(black)Output         

(black)Output         

(blue)0V         

(blue)0V          Load

Output short 

overcurrent 

protection circuit

+

-

Содержание BL Series

Страница 1: ...PN or PNP open collector output Load voltage max 30VDC Load current max 100mA Residual voltage max 1VDC Protection circuit Reverse polarity protection circuit output short overcurrent protection circuit Indicator Operation indicator red LED operation mode indicator green LED Insulation resistance Over 20MΩ at 500VDC megger Noise immunity 240V the square wave noise pulse width 1 by the noise simula...

Страница 2: ...ved light Received light Interrupted light Interrupted light Stable light ON area Unstable operation level Stable light OFF area Incident light level High Low Operation indicator red LED Transistor output The waveforms of Operation indicator and Transistor output are for Light ON it is operated as reverse in Dark ON If short circuit the control output terminal or supply current over the rated spec...

Страница 3: ...Emitter Receiver Anti slip tube Binding band max 2 5mm width Liquid If installing this unit at opaque pipes it is impossible to detect accurately Install this unit at the rated pipes Using binding band Ø6 to 13mm Using protection bracket Ø12 7mm 1 2 inch Protection bracket BK BL13 P sold separately Protection bracket sold separately Choose a location on the pipe and attach the sensor and the prote...

Страница 4: ...nctions Operation mode switching Operation mode lock setting Light ON Operation mode indicator green LED ON Press operation mode switching button once Dark ON 3 sec Operation mode indicator green LED OFF Lock operation mode Unlock operation mode Press operation mode switching button for over 3 sec until operation mode indicator flashes If you press the operation mode switching button less than 3 s...

Отзывы: