background image

A-140

BL Series

 

Features

Liquid Level Sensor for Mounting Pipe (Through-Beam)

● Detects liquid in a transparent/semitransparent pipe  

   diameter Ø6 to 13mm, thickness 1mm

● Compact size: W23×H14×L13mm

● Selectable Light ON/Dark ON operation mode  

   by operation mode switching button

● Easy to check operation status by operation mode indicator   

   [green LED (Light ON: on, Dark ON: off)],  

   operation indicator [red LED]

●  Built-in reverse polarity protection circuit and  

output short overcurrent protection circuit

● IP64 of protection structure (IEC standards)

 

Model

Model

Pipe diameter Sensing type

Power supply

Control output

BL13-TDT

Ø6 to 13mm

Through-beam 12-24VDC 

±10%

NPN open collector output

BL13-TDT-P

PNP open collector output

 

Specifications

Model 

NPN open collector 

output

BL13-TDT

PNP open collector 

output

BL13-TDT-P

Sensing type

Through-beam

Applicable pipe

●Using binding band: Ø6 to 13mm ●Using protection bracket: Ø12.7mm (1/2 inch)

transparent pipes in 1mm thicknes s (FEP (fluoroplastic) or with equivalent transparency)

Standard sensing target

Liquid in a pipe

1

Response time

Max. 2ms

Power supply

12-24VDC  ±10% (ripple P-P: max. 10%)

Current consumption

Max. 30mA

Light source

Infrared LED (950nm)

Operation mode

Light ON/Dark ON operation mode switch button

Control output

NPN or PNP open collector output

●Load voltage: max. 30VDC     ●Load current: max. 100mA   ●Residual voltage: max. 1VDC

Protection circuit

Reverse polarity protection circuit, output short overcurrent protection circuit

Indicator

Operation indicator: red LED, operation mode indicator: green LED

Insulation resistance

Over 20MΩ (at 500VDC megger)

Noise immunity

±240V the square wave noise (pulse width: 1

) by the noise simulator

Dielectric strength

1,000VAC 50/60Hz for 1 minute (between all terminals and case)

Vibration

1.5mm amplitude or 300m/s

2

 at frequency of 10 to 55Hz in each of X, Y, Z direction for 2 hours

Shock

500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Envi

-

ron-ment

Ambient illumination Sunlight/incandescent lamp: max. 3,000

lx for each

 (receiver illumination)

Ambient temperature 10 to 55

, storage: -25 to 65

Ambient humidity

35 to 85%RH, storage: 35 to 85%RH

Protection structure

IP64 (IEC standard)

Material

Case: polycarbonate

Cable

Ø2.5, 3-wire, 1m (AWG28, core diameter: 0.08mm, number of cores: 19, insulator diameter: Ø0.9)

Accessory

Binding band: 2, anti-slip tube: 2

Approval
Weight

※2

Approx. 50g (approx. 13g)

1: This may not detect the liquid with low transparent, with high viscosity, or with floating matters.

2: The weight includes packaging. The weight in parenthesis is for unit only.

The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.

  

Please read “Safety Considerations” 

in the instruction manual before using.

Содержание BL Series

Страница 1: ...PN or PNP open collector output Load voltage max 30VDC Load current max 100mA Residual voltage max 1VDC Protection circuit Reverse polarity protection circuit output short overcurrent protection circuit Indicator Operation indicator red LED operation mode indicator green LED Insulation resistance Over 20MΩ at 500VDC megger Noise immunity 240V the square wave noise pulse width 1 by the noise simula...

Страница 2: ...ved light Received light Interrupted light Interrupted light Stable light ON area Unstable operation level Stable light OFF area Incident light level High Low Operation indicator red LED Transistor output The waveforms of Operation indicator and Transistor output are for Light ON it is operated as reverse in Dark ON If short circuit the control output terminal or supply current over the rated spec...

Страница 3: ...Emitter Receiver Anti slip tube Binding band max 2 5mm width Liquid If installing this unit at opaque pipes it is impossible to detect accurately Install this unit at the rated pipes Using binding band Ø6 to 13mm Using protection bracket Ø12 7mm 1 2 inch Protection bracket BK BL13 P sold separately Protection bracket sold separately Choose a location on the pipe and attach the sensor and the prote...

Страница 4: ...nctions Operation mode switching Operation mode lock setting Light ON Operation mode indicator green LED ON Press operation mode switching button once Dark ON 3 sec Operation mode indicator green LED OFF Lock operation mode Unlock operation mode Press operation mode switching button for over 3 sec until operation mode indicator flashes If you press the operation mode switching button less than 3 s...

Отзывы: