Page 9
IronHorse GSD5 DC Drives User Manual – 1st Ed, Rev E – 05/13/2020
Installation and Wiring – Wiring Diagrams (continued)
GSD5-240-10N4 Basic Wiring Diagram
SPEEDPOT
DPST SWITCH
-11
-9
-8
-4 -5 -6 -7
-1 -2 -3
P2
Inhibit
Pin
P1
P
ot Lo
Wiper
P
ot Hi
-Arm
+Arm
+Field
-Field
AC
AC
motor
armature
ac input**
field*
chassis
ground
Switched AC2
Switched AC1
Min
Max Accel
IR
Comp
Cur.
Lim.
LO (orange)
HI (white)
WIPER (red)
(white)
-10
* Field terminals are used for shunt-wound motors only!
Do not connect these terminals when using
permanent-magnet motors.
** AC1 terminal is internally fused; AC2 terminal is NOT
internally fused. Add external fuse for AC2 if it is
connected to a hot AC line.
Endplate with holes for 1/2" NPT conduit
INSIDE OF COVER
(black
or brown)
(black)
(white
or
yellow)
FACTORY PREWIRING
CUSTOMER WIRING
GSD5-240-10N4-V Basic Wiring Diagram (Factory installed Voltage Follower input option)
3PDT Switch
motor
ac input
INPUT IMPEDANCE:
1.2M
W
on high scale
150K
W
on low scale
-4 -5 -6 -7
P2
Inhibit
Pin
P1
P
ot Lo
Wiper
P
ot Hi
-Arm
+Arm
+Field
-Field
AC
AC
Switched AC
Switched AC
Min
Max Accel
IR
Comp
Cur.
Lim.
-11
-9
-8
-10
-1 -2
Speedpot
(white)
(red)
(yellow)
(brown)
(black)
(blue)
(black)
(red)
(brown)
(yellow)
P2
P4
P3
P5
JP2
-1 -2 -3
4-20 Vin
RANGE
JUMPER
CONNECTOR*
GAIN
TRIMPOT
(white)
(orange)
(orange)
(white)
BALANCE
TRIMPOT
(white)
Vin or 4-20mA
CONNECTOR
-1
-3
NOTE: SOME
FACTORY WIRING
IS NOT SHOWN
FOR CLARITY
analog
speed
signal
analog
speed
common
* Jumper clip is used to select
input voltage range. When
installed from P4-1 to P4-2,
the range is 0–25 VDC thru
0–250 VDC. When installed
from P4-2 to P4-3, the range
is 0–5 VDC thru 0–25 VDC.
FACTORY PREWIRING
GSD5-240-10N4-V
(INSIDE OF COVER)
CUSTOMER WIRING