![AutomationDirect IRON HORSE GSD5 Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/automationdirect/iron-horse-gsd5-series/iron-horse-gsd5-series_user-manual_3021871008.webp)
Page 8
IronHorse GSD5 DC Drives User Manual – 1st Ed, Rev E – 05/13/2020
Installation and Wiring (continued)
Wiring Diagrams
GSD5-240-10C Basic Wiring Diagram
Customer Installed
Speedpot
(factory provided
with 8-inch leads)
P2
Min
Max Accel
IR
Comp
Cur
Lim
Inhibit
Pin
orange white
red
1 2 3 4 5 6 7 8 9 10 11
P1
motor
armature
chassis
ground
field*
AC input **
Pot Lo
Wiper
Pot Hi
–Arm
+Arm
+Field
–Field
spare
spare
AC2
AC1
* Field terminals are used for shunt-wound motors only!
Do not connect these terminals when using permanent-magnet motors.
** AC1 terminal is internally fused; AC2 terminal is NOT internally fused.
Add external fuse for AC2 if it is connected to a hot AC line.
GSD5-240-10C Reversing Wiring Diagram
Arm2
Arm1
AC2* (N)
AC1* (L)
-Armature / -Field (P1-4)
+Armature (P1-5)
VAC Input (N) (P1-10)*
VAC Input (L) (P1-11)*
GSD5-240-10C
* AC1 (P1-11) terminal is internally fused;
AC2 (P1-10) terminal is NOT internally fused.
Add external fuse for AC2 if it is connected
to a hot AC line.
OFF (no wire terminal)
Direction 1 (forward or reverse)
Direction 2 (reverse or forward)
Customer supplied
4PDT Center-off
Center-Blocked switch
(GSDA-MREV shown)