![Automationdirect.com IronHorse GSD Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/automationdirect-com/ironhorse-gsd-series/ironhorse-gsd-series_user-manual_3021948010.webp)
Page 10
IronHorse GSDA-DP-D DC Drives Accessory User Manual – 1st Ed. Rev. A – 11/11/2019
P1 Terminal Block Wiring Diagrams
NOTE: Speed pickups shown above are not required for open-loop operation.
PICK-UP MOUNTED
TO MOTOR SHAFT
AC INPUT
AC INPUT
black
white
red
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
GSDA-DP-D
MASTER
2 AMP
HIGH OUTPUT
WIPER OUTPUT
COMMON
+5VDC
SIGNAL 1
(Mounts on rotating
end shaft with 10-32
tapped hole, 1/2" deep)
P1-9*
P1-10
P1-11
P1-12
}
85-265VAC
}
Form C
Relay output
(Programmable)
Alarm Output - Normally Open
Alarm Output - Common
Alarm Output - Normally Closed
* P1-9 signal input may be programmed for a number of functions,
including jog, inhibit, etc.
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
P1-9
P1-10
P1-11
P1-12
* Optional Inhibit Switch
FOLLOWER PICK-UP
MOUNTED TO
MOTOR SHAFT
black
white
red
white
COMMON
+5VDC
SIGNAL 1
SIGNAL 2
SIGNAL 2
LOW OUTPUT
}
Connect to the speedpot
of the control being driven.
High must be positive
voltage with respect to low.
}
Form C
Relay output
(Programmable)
Alarm Output - Normally Open
Alarm Output - Common
Alarm Output - Normally Closed
AC INPUT
AC INPUT
2 AMP
HIGH OUTPUT
WIPER OUTPUT
}
85-265VAC
LOW OUTPUT
}
Connect to the speedpot
of the control being driven.
High must be positive
voltage with respect to low.
*
black
GSDA-DP-D
FOLLOWER
(Mounts on rotating
end shaft with 10-32
tapped hole, 1/2" deep)
GSDA-PU2x
GSDA-PU2x
Wiring Terminal Functions
•
P1-1 (AC / N) – For single-phase AC systems with a grounded neutral, connect the neutral AC line to
this terminal. For systems with two hot AC lines, connect either of the hot AC lines to this terminal.
•
P1-2 (AC / L) – For single-phase AC systems, connect the hot AC line to this terminal. For systems
with two hot AC lines, connect either of the hot AC lines to this terminal.
•
P1-3 (HI) – This is the POT HI reference terminal. This terminal must be connected to the most
positive speed pot input terminal (minimum 2.5VDC) of the partner control device. This terminal will
generally be referred to as Pot HI or +V for positive supplies, and Com for negative supplies.
•
P1-4 (WP) – This is the Wiper output terminal. This terminal will output an analog voltage signal
proportional to the referenced voltage signals connected to P1-3 (HI) and P1-5 (LO). This terminal
should be connected to the wiper or signal input of the partner control device.
•
P1-5 (LO) – This is the POT LO reference terminal. This terminal must be connected to the most
negative speed pot input terminal of the partner drive. This terminal will generally be referred to as Pot
LO or Com for positive supplies and –V for negative supplies.
•
P1-6 (COM) – This is the common point for the control logic. The speed sensor common lead as well
as any other equipment or source needing to reference the control common will be connected to this
terminal.
•
P1-7 (+5V) – This is a self-con5VDC power supply capable of up to 50 mA. The speed sensor