![Automatic Technology GDO-9V1 SecuraLift Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/automatic-technology/gdo-9v1-securalift/gdo-9v1-securalift_installation-instructions-manual_3021670023.webp)
FINAL SET UP
23
23. SETTING OF COURTESY LIGHT TIME
The preset courtesy light time on the door opener is
3 minutes. This time can be changed by the following:
1.
Press in and hold both the Auto Close Time button
and Force Margin Set button (Fig. 43).
2.
While holding in the two buttons, press the Plus (+)
button. Each press of the button will add 10 seconds
to the light time.
3.
To decrease the time follow Step 1 and press the
Minus (-) button. Each press will deduct 10 seconds
from the light time.
4.
To recall the factory set default light time press in and
hold together the Auto Close Time button, the Force
Margin Set button and the Set button for about
2 seconds. Release all buttons, the factory set
default of 3 minutes will be recalled.
24. SETTING THE PET MODE DOOR OPENING
POSITION.
The default PET (Pedestrian) position is factory preset
to a predetermined height. The PET mode status is
indicated by both the Open and Close Limit LED’s being
illuminated. The default position can be changed by the
following:
1.
Make sure the door is in the closed position. Press
and hold the Plus (+) button for six (6) seconds
(Fig. 44), you should hear three beeps and the Open
and Close LEDs will flash rapidly.
2.
Press the Plus (+) or Minus (-) button (Fig. 44) to
move the door to your required new pet open door
position.
3.
Press the Set button (Fig. 44) to record the new
position.
The Pet mode is activated from a transmitter button
coded to that function. When activated the door drives to
the preset position from either above or below. If the Pet
button is pressed while the door is moving the door will
be stopped. If the Pet button is pressed when the door
is in the Pet position, then the door will be closed. No
auto close is enabled.
25. INSTALLATION OF WALL MOUNTED
TRANSMITTER HOLDER
1.
Mount the holder in a location out of reach of children
and convenient to the customer. (Fig 45). Make sure
the door is visible from this location.
2.
The transmitter can be easily clipped in and removed
from the holder as required.
3.
To set the transmitter codes refer to Step 18 on
Page 19.
26. RE-INITIALIZING THE OPENER
To re-initialize the opener press and hold the Set Button
for two (2) seconds, the beeper will sound once. The
door will start to move and re-calculate force margins.
The door can move between the open and close limit
positions up to four (4) times (depending on the position
of the door and the power up condition). A single beep
will be heard once the initialization is complete. The
door is now ready for use.
FIG. 43
FIG. 45
FIG. 44
FIG. 45