![Automatic Technology GDO-2 SecuraLift Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/automatic-technology/gdo-2-securalift/gdo-2-securalift_installation-instructions-manual_3021656005.webp)
5
OPERATING CONTROLS
1. LIGHT CODE button
(white) is
used for storing or erasing the
transmitter button (code) you wish to
use to switch the courtesy light on the
opener on or off.
2. CODING LED
(red) light flashes
when a code is being stored or when a
transmitter button is pressed.
3. DOOR CODE button
(blue) is used
for storing or erasing the transmitter
button you wish to use to command the
door to open, stop or close.
4. DOOR STATUS LED
(Yellow)
5
.
CLOSE drive button
(red) is used
during installation to help set the close
limit position. Pressing and holding this
button will move the door in the close
direction. Movement stops when the
button is released.
NOTE: The close safety obstruction
detection is inoperable whenever the
Open or Close Drive button is used to
move door.
6. CLOSE LIMIT LED
(red) the led
is very helpful during installation. It
illuminates and flashes when the door is
closing and remains steady on when the
close limit position has been reached.
7. AUTO CLOSE TIME button
(White) is used to adjust the auto close
time. While holding in the auto close
button and then pressing the open
button the time is increased. Each press
will increase the time by 5 seconds.
Pressing the close button will decrease
the time.
8. SET button
(yellow) is used during
the installation phase together with the
Open and Close buttons to set the door
limit positions. The Set button is also
used to re-initialise the Opener.
9. O/S/C button
(Yellow) is used
during installation to test the open, stop
and close cycles for the opener. The
opener has to be initialised by the Reset
button before the O/S/C button becomes
operable.
10. OPEN DRIVE button
(green) is
used during installation to help set the
open limit position. Pressing and
holding this button will move the door
in the open direction. Movement stops
when the button is released.
NOTE: The open safety obstruction
detection is inoperable whenever the
Open or Close Drive button is used to
move door.
11. OPEN LIMIT LED
(green) the
led is very helpful during installation. It
illuminates and flashes when the door is
opening and remains steady on when
the open limit position has been
reached.
12. FORCE MARGIN SET Button
The obstruction force pressure is set
automatically by the opener during
installation. The pressure can be
adjusted manually using the Force
Margin Set button (White). Pressing the
force margin set button and open or
close button will increase or decrease
the amount of force. The Force Margin
Set is only ever used if other
environmental factors (wind, etc.)
effect the operations of the door/opener.
13. P. E. SHUNT.
The shunt has to be
removed when connecting a Photo
Electric Beam.
NOTE: P.E. SHUNT
must not be
removed otherwise the opener will not
function correctly. Remove only when a
P.E beam is to be connected.
14. PROG INPUT
is used for the
connection of the ATA Universal
Programmer for the purpose of editing
control and receiver functions.
15. O/S/C INPUT
is used for the
connection of a wired switch
(momentary contact). This switch can
then be used to open, stop or close the
door. Install the wall switch in a
location where the switch is out of reach
of children and the garage door is
visible.
16. ENGAGE/DISENGAGEMENT
CORD
when pulled down and released
this will select manual mode on the
opener, particularly when there is a
power failure. Pulling down and again
releasing will select automatic mode on
the opener. The length of the string is
adjustable.
17. EASY ACCESS
TRANSMITTER
The
“manual release”
engage/disengagement handle has
within its housing a wireless
transmitter. If the button is pressed it