SETTING LIMITS
STEP 15
SETTING TRAVEL LIMITS POSITIONS
METHOD ONE: VIA THE CONTROL PANEL
IMPORTANT NOTE: The O/S/C button will not function
until the open and close limits positions are set.
15.1 SETTING LIMITS POSITIONS
1.
Plug the drive unit power cord into mains power point and
switch power on.
2.
Check that the door is open approximately half way. If not
move it by hand.
3.
Engage the shuttle into chain index. If necessary use the Red
Close button or Green Open button to inch the index to engage
the shuttle.
NOTE:
The door and shuttle must be engaged into the chain
index and should be in the approximate half way position.
4.
Depress red close button and hold it, the door will start
closing. Release the button once you have reached your desired
closed limit position. (
Fig. 19
)
5.
Press the set button (
Fig. 19
). This action will store into
memory the closed limit position.
6.
Press the green open button (
Fig 19
), the door will start
opening. Release the button once you have reached your
desired opened limit position.
IMPORTANT WARNING: Please be aware that the garage
door will start closing automatically once step 7 is
performed. The door will also automatically re-open after
fully closing with a small pause between the cycles.
7.
Press the Set button (
Fig. 19
). This action will store into
memory the open limit position. The door will now
automatically close to its limit position then fully open to
calculate the safety obstruction forces (ISS). Please be aware of
the above warning. The opener can now be operated from the
O/S/C Button.
15.2 RESETTING DOOR LIMIT POSITIONS
The door travel limit positions can be deleted for new
positions by the following steps below:
1.
Press and hold the Close button (
Fig. 19
) for six (6) seconds
until you hear three beeps and the red Close Limit LED starts
to flash. Release the button.
2.
Follow STEP 15.1 1 to 7 to set new travel limit positions.
Go to STEP 17 and test the Safety Obstruction Force.