Страница 1: ...ions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please save these instructions for future reference Installation Instructions FEA ATURING ALPS Autom atic Lim its Positioning System FEA ATURING ALPS Autom atic Lim its Positioning System ...

Страница 2: ...necting Photo Electric Beam Setting Auto Close Time Setting Courtesy Light Time Setting Pet Mode Door Opening Position Re Initialising Door Opener Door Status Indicators Buttons and Functions Factory Default Settings Technical Specifications Trouble Shooting Guide Parts List Warranty 3 4 5 7 8 9 10 11 12 13 14 15 16 18 18 19 19 19 20 20 21 21 22 23 24 Purchased From _______________________________...

Страница 3: ...he wall switch or wall mounted transmitter in a location where it is out of reach of children and the garage door is visible The door opener is not intended for use by young children or infirm persons without adequate supervision Children should be supervised to ensure that they do not play with the remote transmitters or the opener Keep hands and loose clothing CLEAR of the door and door opener a...

Страница 4: ... should be checked at least once a month See installation manual for instructions SECURITY CODE STORE The SecuraLift Garage Door Opener uses state of the art technology in storing your selected transmitter security code Up to 23 different transmitters can be stored in the openers memory OVER LOAD INDICATOR When the maximum opening and closing capacity of the opener is exceeded an audible beeper wi...

Страница 5: ...on Pressing and holding this button will move the door in the open direction Movement stops when the button is released NOTE The open safety obstruction detection is inoperable whenever the Open or Close Drive button is used to move door 11 OPEN LIMIT LED green the led is very helpful during installation It illuminates and flashes when the door is opening and remains steady on when the open limit ...

Страница 6: ...D 6 CLOSE LIMIT LED RED 7 AUTO CLOSE BUTTON WHITE 8 SET BUTTON YELLOW 9 O S C BUTTON YELLOW 10 OPEN DRIVE BUTTON GREEN 11 OPEN LIMIT LED GREEN 12 FORCE MARGIN SET BUTTON 13 P E SHUNT 14 PROG INPUT 15 O S C INPUT 16 ENGAGE DISENGAGEMENT CORD 17 ENGAGE DISENGAGEMENT HANDLE EASY ACCESS TRANSMITTER 1 2 3 4 5 6 7 12 10 11 16 17 13 14 15 9 8 ...

Страница 7: ...NG TRANSMITTER PTX 4 2 EASY ACCESS TRANSMITTER EAT 1 Not available all models 1 WALL MOUNT BRACKET FOR PTX 4 1 BATTERY A23 12V ALKALINE 2 TUBES 5 TUBE INSERTS 4 PIPE SUPPORT ASSEMBLY 1 CHAIN 1 SHUTTLE TROLLEY ASSEMBLY 2 DOOR ATTACHMENT ARMS 2 ACCESSORY PACK 1 INSTALLATION MANUAL 1 ...

Страница 8: ...r is to be fitted to a one piece door without track exchange the 10 teeth sprocket on drive unit with a 7 teeth drive sprocket available as an option from ATA IMPORTANT If using a track type door often referred to as a sectional or track tilt door use only 10 teeth drive sprocket on the drive unit If using a one piece door without tracks use the 7 teeth sprocket on drive unit STEP 3 Attach one end...

Страница 9: ... tracks Fig 4 proceed with the installation from Step 5 z For a one piece door without tracks on springs Fig 5 proceed with the installation from Step 9 Remember a one piece door without tracks requires a 7 teeth drive sprocket FIG 3 FIG 4 FIG 5 SECTIONAL DOOR WITH TRACK DOOR TRACK PROCEED FROM STEP 5 ONE PIECE DOOR WITH TRACK DOOR TRACK PROCEED FROM STEP 5 ONE PIECE DOOR WITHOUT TRACK DOOR PROCEE...

Страница 10: ...ssembly to wall bracket with 90 mm long clevis pin and secure with supplied spring clip Fig 8 leaving drive unit in its packing box for protection during installation STEP 8 Raise the drive unit from the packing box and support it in a horizontal position with a step ladder then open the garage door Rest the opener on the open door and use a scrap piece of wood to bring it to horizontal level Line...

Страница 11: ...ed by the top edge of the door as it moves Stop the door when it is at its highest point of travel Fig 12 Allow 25mm additional height for clearance between the door and the track Support pipe tube in this position and the close the door Fig 12 This will be the height to mount the wall bracket Top of door must not touch tube WARNING THE OPENER MUST BE SECURELY FASTENED TO A STRUCTURAL SUPPORT OF T...

Страница 12: ...on Always use the bend straight arm If installing on a door with bad wave action lengthening the arm even further will assist the door operation by reducing the wave action THE EASY ACCESS TRANSMITTER The Easy Access Transmitter is prepared ready for use with the battery pre installed Before the transmitter can be operational the Transmitter Code has to be stored into the openers memory To store t...

Страница 13: ...ed limit position 6 Press the green open button Fig 19 the door will start opening Release the button once you have reached your desired opened limit position IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 7 is performed The door will also automatically re open after fully closing with a small pause between the cycles 7 Press the Set button Fig 19...

Страница 14: ...tion 10 Press button 1 Fig 20 the door will start opening Release the button once you are 1 to 2 cm from your desired open limit position Press button 3 for two seconds then release 11 Press button 1 Each press will enable you to inch the door to your desired closed position IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 12 is performed The door w...

Страница 15: ...ually not necessary to adjust the Safety Obstruction Force The only time the force may need to be increased is due to environmental conditions for example windy or dusty areas and areas with extreme temperature changes 17 3 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button Fig 22 2 While holding down the Force Margin button press the Open button Fig 22 Each press increases th...

Страница 16: ... 18 3 SETTING THE TRANSMITTER TO OPERATE PET PEDESTRIAN MODE 1 Press and hold Door Code button and the Close button FIG 26 2 Press the button on the transmitter you would like to use to control pedestrian mode for two seconds pause for two seconds Press the same button again on the transmitter for two seconds 3 Release all buttons to store the transmitter in memory 4 Press the transmitter button t...

Страница 17: ...conds the button should now be recorded 5 Wait for 10 seconds and then press the recorded transmitter button to see if it operates the door 20 DELETING PROGRAMMED CODES 20 1 DELETING A STORED TRANSMITTER CODE 1 Select the transmitter you want to delete 2 Press and hold the Door Code button Fig 28 3 Press the transmitter button you would like to delete for two seconds Pause for two seconds Press th...

Страница 18: ...DE The Auto Close timer will only start after the Photo Electric Beams P E path is broken and the auto close time has been set If the P E path is not broken the door will remain open till the path is broken If the Door Opener incurs an obstruction not from the P E while closing the door will re open and not auto close until the part of the P E beam is broken again SETTING AUTO CLOSE TIME 1 Press i...

Страница 19: ...ttons Fig 32 to move the door to your required new pet open door position 3 Press the Set button Fig 32 to record the new position The Pet mode is activated from a transmitter button coded to that function When activated the door drives to the preset position from either above or below If the Pet button is pressed while the door is moving the door will be stopped If the Pet button is pressed when ...

Страница 20: ...ruction force margin setting Force Margin Set then Set Reloads the factory set default obstruction force margin setting Auto Close Time then Open Increases the auto close delay time Auto Close Time then Close Decreases the auto close delay time Auto Close Time then Set Reloads the factory set default auto close delay time Force Margin Set Auto Close Time then Open Each press of the open button inc...

Страница 21: ...ER BATTERY CR1220 Lithium 3 Volts GLOBE Edison screw mount 240V 60W Rough Service or construction type DEFAULT SETTINGS AND SPECIFICATIONS 21 Note 1 The maximum door opening on which the SecuraLift can be installed is 5100mm wide by 2400mm high The door must be well balanced A person should be able to lift the door up manually with very little effort in case of an emergency 2 Intermittent operatio...

Страница 22: ...t limits positions Step 15 2 Page 13 Door will not open fully Door limits positions need to be reset Reset limits positions Step 15 2 Page 13 Courtesy light not working Globe blown Replace globe Edison Type 240V 60W Globe keeps blowing Incorrect globe voltage must be 24V DC Replace globe Edison Type 240V 60W Auto close not working PE Beam or wiring faulty PE Beam not aligned correctly PE Beam is o...

Страница 23: ...SPARE PARTS LIST 23 WHEN ORDERING SPARE PARTS PLEASE QUOTE THE ORDER CODE NUMBER TO YOUR YOUR INSTALLER DISTRIBUTOR ...

Страница 24: ...tions set out in installation instruction manual m attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs n faulty or unsuitable wiring of structure to which the product is fixed or connected o radio including citizen band transmission or any electrical interference p damage...