6
AM800, AM808 & AM888
Dominator Instruction Manual
J1
3. Operating controls
Fig.3.1
(1) 24V power input connector-
Terminal is used to connect Vac to the control board.
(2) 10Amp fuse.
10 Amps fuse to protect the electronic circuit board.
(3) SBC02 Battery Backup Connector
This connector is used to connect Battery Charger SBC02 to the
opener.
(4) Motor connector
DC 24V motor connects to this connector.
(5) OPERATE (Blue) button
Operate (blue) Button is used during installation to test the
open, stop and close cycles for the opener. The opener has to
be initialised by the Limit set button before the Operate Button
becomes operable.
(6) Plus (+) (Green) button
Plus (+) Green Button is used during installation to help set the
open limit position. Pressing and holding this button will move the
door in the open direction. Movement stops when the button is
released.
(7) PG-3 Programmer connector
Prog input is used to connect a PG-3 Programmer for editing
functions, diagnostic purposes and accessing special features.
(8) Open Limit LED
Open Limit (Green) LED illuminates and flashes when the door is
opening and remains steady on when the open limit position has
been reached.
(9) FORCE MARGIN SET Button
Force Margin Set The obstruction force pressure is set automatically
by the opener during installation. The pressure can be adjusted
manually using the Force Margin Set Button. Holding the Force
Margin Set Button and pressing the Plus (+) or Minus (-) Button will
increase or decrease the amount of force. The force margin set is
only ever used if other environmental factors (wind, etc..) Affect the
operations of the door/opener.
(10) Close Limit LED
Close Limit Red LED illuminates and flashes when the door is
closing and remains steady on when the close limit position has
been reached
.
(11) Minus (-) (Red) CODE SET button
Minus (-) Red Code Set Button is used during installation to help
set the close limit position. Pressing and holding this button will
move the door in the close direction. Movement stops when the
button is released.
(12) Code Set LED
Code Set LED light flashes when a code is being stored or when a
transmitter button is pressed.
(13) LIMIT SET Button
Limit set Button is used during the installation phase together with
the open and close buttons to set the door limit positions. The
Limit set button is also used to re-initialise the opener.
(14) 14.Service LED
Service LED (yellow) indicates when the opener requires service or
repairs.
(15) 15.Courtesy light module Connectors
Courtesy LED Light Module Connectors are used to c24V
LED light modules.
(16) Accessories Connector (J4) (Terminal Block):
V+
(+35V/+24V) is used to power Accessories such as external
receiver (200mA max).
SB1
(mandatory) input is used to connect to Safety Beam.
0V
is a 0 volt connection for Safety Beam.
SB2
input is used to connect to Safety Beam.
0V
is a 0 volt connection for Safety Beam.
OSC (Operate)
is used for the connection of a wired switch
(momentary contact). This switch can then be used to open, stop
or close the door. Install the wall switch in a location where the
switch is out of reach of children and the garage door is visible.
AUX
allows the opener to operate other devices such as an
alarm system.