EC declaration of conformity

W

e, undersigned,

AUTOMA

TIC SYSTEMS s.a.

Avenue Mercator

, 5

1300 W

avre 

BELGIQUE 

Herewith declare that the following machine

Tripod turnstile

TL1, TL2

is 

in 

accordance 

with 

the 

conditions 

of 

the 

following 

Directives, 

standards 

and 

other 

specifications:

Machinery Directive 2006/42/CE.

Low-voltage Directive 2014/35/UE.

Electromagnetic compatibility Directive 2014/30/UE.

Directive RoHs (Restriction of Haz

ardous Substances) 2011/65/EU.

EN 12100:2010: Safety of machinery – General principles for design - Risk assessment and

risk reduction (ISO 12100:2010).

IEC 60204-1 / A1 : 2009: Safety of machinery - Electrical equipment of machines -

Part 1: General requirements.

EN 61000-6-3 / A1 : 2011: Electromagnetic compatibility (EMC). Generic standards. Emission

standard for residential, commercial and light-industrial environments.

IEC 61000-6-2 : 2016: Electromagnetic compatibility (EMC). Generic standards. Immunity

standard for industrial environments.

International & Headquarters

AUTOMA

TIC SYSTEMS SA

Email: 

[email protected]

Tel.: +32.10 23 02 27

Fax.: +32.10 86 22 90

Belgium

W

allonia-Brussels

Tel.: +32 70 22 44 66

Fax.: +32 10 86 22 90

Email: 

[email protected]

Belgium

Flanders

Tel.: +32 70 22 44 66

Fax.: +32 3 88 700 76

Email: 

dnv

[email protected]

Canada

Tel.: +1 450 659 0737

Fax.: +1 450 659 0966

Email:

 

[email protected]

China

Tel.: +86 512 5383 0561

Email: 

[email protected]

Deutschland

Tel.: +49 2303 553 4040

Fax.: +49 2303 553 4049

Email: 

[email protected]

France

Tel.: +33 1 30 28 95 53

Email: 

[email protected]

Spain

Tel.: +34.70.22.44.66

Fax.: +32.10.86.22.90

Email: 

[email protected]

United Kingdom

Tel.: +44 (0) 1604 654 210

Fax.: +44 (0) 1604 654 110

Email: 

[email protected]

m

United States

Tel.: +1 450 659 0737

Fax.: +1 450 659 0966

Email: 

[email protected]

Latin America

Tel.: +1 450 659 0737

Fax.: +1 450 659 0966

Email: 

[email protected]

The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose 
other than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic 
Systems. The document is subject to change without notice.

Содержание TriLane TL2

Страница 1: ...TriLane TL2 www automatic systems com TRIPOD TURNSTILE TL2 Quick Start Guide QSG Installation Instructions and Getting Started Translated from the original French version Rev 03 ...

Страница 2: ...ns on the equipment must be carried out by qualified personnel Any work on this product that is unauthorized or carried out by an unqualified technician will automatically void the manufacturer s warranty о о Access to the mechanism must be reserved for staff who are aware of the electrical and mechanical risks incurred in case of negligent handling о о For any operation that does not require the ...

Страница 3: ...ation label showing the equipment type the production date the voltage the weight and the serial number and the reference code 4 GENERAL 4 1 GENERAL CONDITIONS OF USE Your TriLane tripod turnstile has been designed to operate in any kind of climatic environment from 10 C to 50 C with up to 90 of relative humidity 4 2 PACKAGING In most cases your turnstile will be delivered in a cardboard box attac...

Страница 4: ... side and in direction B when the tripod is on his left side 4 5 LOCATION OF THE ELECTRICAL COMPONENTS 4 16 4 21 4 15 4 18 4 17 4 19 4 20 4 22 Ref Designation 04 15 Support for electronic devices 04 16 DIN rail 04 17 Power supply 24 VDC 4 A 04 18 Main switch If you open the casing turn off the equipment by switching off the main switch 04 19 Earth terminal 04 20 Terminal block stop 04 21 Protectiv...

Страница 5: ...ools Flat spanner set Set of Allen keys Spirit level Hammer drill concrete drill bit Ø 15 x 100 Standard protective equipment gloves goggles hard hat and safety shoes 5 2 PRELIMINARY WORK The turnstile has been specially packaged for transport Bring the material to the installation site with the help of a forklift truck and remove the packing material Unlock the locks 4 10 and open the cover 4 4 T...

Страница 6: ...h right or left end box EXPANSIBLE ANCHOR B15 30 3413 000 Suggested reference M10 Ø 60 mm PVC SHEATH Concrete Wiring to provide for 230 V single phase power supply ground in 3G2 5 IP CABLE Ethernet STP CAT 5 Dimensions according to standard Automatic Systems anchoring The information contained in this document is the property of Automatic Systems and is confidential The recipient shall refrain fro...

Страница 7: ...ly Ensure that the turnstile remains firmly fixed to the ground by tightening the expandable dowels Ensure that the cables can pass through Make sure that all the housings of the battery are perfectly aligned and horizontal If needed add shims between the housings and the floor to ensure that they are perfectly level 5 6 INSTALLING THE STAINLESS STEEL ARM VERSION WITH FIXED ARMS 5 1 4 6 5 2 L O C ...

Страница 8: ... 2 Install and lock the cover Fig 4 page 5 4 4 Check the functionalities Pictograms locking mechanism fraud detection performing a few passages in both directions The tripod turnstile is now operational All the settings have been made in the factory at the time of the working tests Some additional adjustment could nevertheless be necessary as a result of transport or handling during assembly In su...

Страница 9: ...retain the surface appearance and avoid any oxidation deposits or marks it is strongly recommended to regularly treat the stainless steel surface with a product specially designed for this purpose Automatic Systems can provide an approved product under reference 6031 000 Automatic Systems reserves the right to deny warranty coverage in the case of an apparent lack of maintenance The information co...

Страница 10: ...ctro magnet from heating up The turret will not re lock during rotation Check the operation of the angular sensor and the connecting cable CN17 on the AS1635 circuit board In the case of an angular sensor problem an error appears on the HMI display The TriLane does not operate and the LED LD1 on the AS1635 circuit board is off The AS1365 control circuit board is not powered with 24 VDC Check the 2...

Страница 11: ...atic systems com Tel 32 10 23 02 27 Fax 32 10 86 22 90 Belgium Wallonia Brussels Tel 32 70 22 44 66 Fax 32 10 86 22 90 Email helpdesk be automatic systems com Belgium Flanders Tel 32 70 22 44 66 Fax 32 3 88 700 76 Email dnv be automatic systems com Canada Tel 1 450 659 0737 Fax 1 450 659 0966 Email helpdesk nam automatic systems com China Tel 86 512 5383 0561 Email helpdesk cn automatic systems co...

Отзывы: